











heating and cooling heat pump integrates air conditioning and heating systems, is comfortable and energy-saving, and will surely lead the market trend of comfortable home life in the future.
How exactly does the heating and cooling heat pump work?
What is the basic principle of heating and cooling heat pump?
Will the floor height affect the installation of the heating and cooling heat pump?
The common heating and cooling heat pumps on the market are almost all of combined cooling and heating, which solves the problems of cooling in summer and heating in winter through a set of equipment. In some specific areas (the temperature is relatively high in winter), the air energy heat pump can also be connected to the domestic hot water tank to provide 24-hour uninterrupted hot water for the family, so the air energy heat pump can be used for cooling and heating, as well as cooling and heating. And with domestic hot water, but in order not to affect the heating effect, the domestic hot water is generally not combined.
Basic principle of heating and cooling heat pump: it is mainly composed of compressor, heat exchanger, axial fan, thermal insulation water tank, water pump, liquid storage tank, filter, electronic expansion valve and electronic automatic controller. After the power is turned on, the axial flow fan starts to operate. The outdoor air is heat exchanged through the evaporator. The air with reduced temperature is discharged from the system by the fan. At the same time, the working medium inside the evaporator is sucked into the compressor. The compressor compresses the low-pressure working medium gas into high-temperature and high-pressure gas and sends it to the condenser. The water forcibly circulated by the water pump also passes through the condenser and is heated by the working medium and sent to the user for use, The working medium is cooled into liquid, which flows into the evaporator again after throttling and cooling by the expansion valve. In this way, the heat energy in the air is continuously "pumped" into the water, so that the water temperature in the insulation water tank gradually rises to about 55 ℃, which is just suitable for people to take a bath. This is the basic working principle of heating and cooling heat pump.
The floor height problem, many people think that the floor height of the elevator apartment is relatively low, and the installation of heating and cooling heat pump will cause the room to become depressed, but in fact, the installation of heating and cooling heat pump will not have much impact on the floor height. , The concealment of central air-conditioning can reduce the sense of oppression of the floor height through the reasonable planning of the ceiling, and the floor heating can also be laid by dry floor heating. The floor height is only increased by 3-4 cm, and the user cannot distinguish it with the naked eye.
Guangdong JNOD New Energy Technology Co., LTD. is the leading manufacturer sofa manufacturer specializing in heating and cooling heat pump. If you want to get more information, just go and connect them.
The heat pump water heater uses a heat pump to absorb the air heat source to produce hot water. The energy saving efficiency is more than 3 times that of the electric water heater. It is more energy efficient than the solar water heater.
What is a direct heat pump water heater?
What are the characteristics of direct heat pump water heaters?
What is the main structure of the direct heat pump water heater?
The direct heat pump water heater is also known as the fast or fast heat pump water heater. The basic characteristics of the direct heat pump water heater are: cold water and superheated water, as long as the tap is turned on, the energy source will continuously supply hot water within a few seconds. Turn off the faucet when you don't need hot water.
According to different heating forms, direct heat pump electric water heaters can be divided into the following three types:
①, bare electric wire heating electric water heater;
②, electric film heating electric water heater;
③, electric heating tube heating electric water heater.
The heater of the direct heat pump water heateris set in a tank frame, which cannot withstand too high water pressure. At the same time, the left and right poles of the tank frame and the two poles introduced by the heating wire will be affected by water pressure for a long time. be damaged. Therefore, direct heating heat pump water heaters cannot be made into the post-system, but are all made into the front-system. In addition, in order to ensure the safe use of direct-heat heat pump water heaters and no dry burning occurs, a pressure sensing activation switch with water flow as a signal is installed at the cold water inlet, and the pressure sensing activation switch diaphragm can withstand the pressure. It is limited and cannot withstand pressure for a long time, so direct heat pump water heaters are generally made into the former system.
A typical direct heat pump water heater is mainly composed of a heating tank plate, a pressure sensor, a power regulator, a water volume adjustment faucet, a water inlet pipe and a water outlet pipe component, among which the heating tank plate is the key component of the direct heat pump water heater. It consists of a groove weight, a sealing ring, a cover and an electric heating element, and the electric heating element is located in the groove of the groove plate.
The direct heat pump water heater works by direct conduction heating. Since the electric heating element is placed in the groove of the groove plate, when the cold water flows through the groove, it can directly flow through the surface of the heating element to be heated. And because the water tank is like a snake, the cold water flowing into the water inlet is gradually heated, and hot water with a higher temperature can be obtained at the water outlet.
Guangdong JNOD New Energy Technology Co., LTD. can produce standard products under clients' brand, modify the products to satisfy client's personalized requirements and work together with clients to design and produce totally new products.
Dragon Boat Festival is a traditional Chinese holiday which falls on the fifth day of the fifth lunar month.
In 2022, Dragon Boat Festival falls on June 3 (Friday). JNOD will have 3 days of public holiday from Friday (June 3) to Sunday (June 5).
The two main activities during the festival are eating zongzi (rice dumplings) and boat races.
Zongzi are the most traditional Dragon Boat Festival food. It’s made of glutinous rice filled with meats, beans, and other fillings. They are wrapped in triangle or rectangle shapes within bamboo or reed leaves and tied with soaked stalks or colorful silky cords.
Dragon Boat races are the most exciting part of the festival, During the competition, Boatmen row the boat in cadence with the drumbeats, as the captain standing in the bow of the boat waves a small flag to help coordinate the rowing. The boat racing is very spectacular with drums beating and colorful flags waving, thousands of people cheering for their team to grab the flag at the end of course.
What do you want to do after an exciting dragon boat race? Yes, it is necessary to take a hot shower. Our built-in 35L electric boiler can quickly provide large flow of domestic hot water, and it only takes 5 minutes to enjoy the bath, which is a very good choice.
We also have many kinds of electrical boiler for optional, Please check out JNOD's website for more details, any inquiries please feel free to contact us.
JNOD has a complete heat pump industry chain, and its products involves Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer,etc.The ultra-low temperature EVI heat pump has been widely used, too.
The inverter technology is considered a perfect solution when it comes to energy-efficiency and economical operation. In an inverter model from a heat pump inverter manufacturer, the cooling and heating are automated in an energy-efficient and seamless manner whereas earlier technologies used to consume a lot of electricity irrespective of the required usage.This will be good to cut-off your electricity bill.
The compressor motor used by DC inverter heat pump manufacturer does not turn on and off all the time but keeps working at low power. This kind of machine makes the operation more quite.
Unlike non-inverters, they don't automatically turn on and off every time they reach a certain temperature; instead, they just cruise along maintaining and regulating the temperature constantly.
The technology and hardware employed in DC inverter model by DC inverter heat pump supplier not only makes the cooling and heating effect more efficient, but also makes the unit last longer. Contrary to the operation of a non-inverter unit, the inverter uses less power and as a result, they work less, meaning that they are less prone to wear and tear.
The DC inverter heat pump is able to cool and heat your room faster than its non-inverter counterpart. This is due to the fact that an inverter heat pump unit operates on a variable speed compressor rather than at a fixed speed one. This process ensures rapid air conditioning effects via faster variable speed allowing the compressor to run at full power only when required while constantly regulating the temperature as per end user's desire.
A smart DC Inverter heat pump will provide you complete control over energy consumption and usage through your PC and portable smart devices. Moreover, it will give you complete insights about all technical metrics such as watts, voltages, current and units consumed. A smart heat pump also lets the user schedule the heat pump to automatically turn itself on or off. Operations of a heat pump are more flexible and centralized when it is smart.
Please feel free to contact our JNOD sales team when you get more information.
Air heat pump water heater has low energy consumption (power consumption saves more than 2/3 compared to conventional electric water heaters), high thermal efficiency (heating speed is four times higher than conventional electric water heaters), Environmental protection and energy saving (reduces more than 2/3 compared to conventional electric water heaters) carbon dioxide emissions).
What are the differences between heat pump water heaters and air conditioners?
Why do heat pump water heaters improve the consumer experience?
What is the working process of the heat pump water heater?
The operating mode of the heat pump water heater is very different from that of the air conditioner, which determines the difference in the design concept between the heat pump compressor and the air conditioner compressor. Trouble-free, long-term stable operation of heat pump water heaters Compared to air conditioning systems, there is a big difference in the operating time. The operating time of heat pump water heater systems is much longer than that of air conditioning systems. The operating time of a heat pump water heater depends on the following factors: Air conditioning systems are often used in summer, but water heaters are mass-produced and run particularly long in winter. The time for heating a water tank in winter is several times as long as in summer, so it is necessary to confirm the operating mode of the heat pump water heater in winter.
According to statistical calculations, 2/3 of the service life of the heat pump water heater is consumed in winter. Since the water outlet temperature of the heat pump is over 55°C, the temperature of the water tank decreases when using. The liquefaction temperature is the main factor affecting the service life of the compressor. Under the condition of simultaneous operation, the total load of the compressor in the heat pump water heater is much higher than that of the compressor in the air conditioning system. The main motivation for consumers to buy water heaters with heat pump is energy saving and comfort. Consumers will thus consume more water, which also extends the working time of the heat pump. If the heat pump water heater is used for heating and service water applications, it can run for a long time during the heating period. From the combination of the above factors, it is evident that the main motor of the heat pump water heater will develop in the direction of miniaturization, and the actual operating time will be greatly extended.
A water heater with compression heat pump mainly consists of evaporator, compressor, condenser and expansion valve. Thermal Circular Process Throttling → Re-evaporation, whereby heat from the environment is transferred to the water.
Guangdong JNOD New Power Technology Co., LTD. sales team has extensive experience in overseas markets. We provide sincere and professional services, including OEM/ODM/project services, technology support, market analysis, use of design and assembly of installation. We have provided marketing consulting services and business solutions to customers from over 40 countries.
With the soaring price of gas and the emphasis on environmental protection in many countries around the world, heat pumps are becoming more and more important and popular among consumers and manufacturers. In the last 2 years, many various kinds of heat pumps have appeared on the market. In this article, we will teach you how to choose a good hybrid hot water heat pump, also called all in one heat pump water heater.
For a hot water heat pump, the water tank is very important, both the outcase and the interior are very important.
* Internal
At this point, we would recommend our customers to choose a hot water heat pump with an enameled water tank for the following reasons.
A. Good thermal insulation: Take JNOD's all in one heat pump with enameled tank as an example. After testing, when the water in the tank is boiled to the set temperature and then power off, the water in the tank will only have a temperature drop of 5-8 degrees Celsius after 24 hours. Such a hybrid heat pump is your wise choice.
B. Strong corrosion resistance: In areas with bad water quality, there are more impurities in the water. If you use the general iron water tank, the welding joints inside are prone to chemical reaction with impurities, which leads to the problem of water leakage.
* Outcase
Here we recommend that consumers choose galvanized steel plate as the shell material. There are businesses in the market will choose color plate. The service life of the color plate is very short, only 1-2 years. A long time inside the box exposed will also lead to water leakage problems in the tank.
Expect these suggestions will let you choose a better heat pump! Feel free to contact JNOD with any questions! Link:https://www.jnodheatpump.com
The Heating and Cooling Heat Pump is driven by an electric motor, uses the heat in the air as a low-temperature heat source, exchanges heat through the air conditioner condenser or evaporator, and then passes through the circulation system to extract or release heat energy, and use the unit circulation system to transfer the energy to the building. It can meet the needs of users for domestic hot water, floor heating or air conditioning.
What is the cycle between the Heating and Cooling Heat Pump and the natural environment?
What is the principle of Heating and Cooling Heat Pump?
Does the Heating and Cooling Heat Pump make noise?
The compressor outlet of the Heating and Cooling Heat Pump is high-temperature and high-pressure gas, which is transformed into a high-pressure and low-temperature vapor-liquid mixture through the heat exchange of the condenser. The low-temperature gas enters the evaporator to evaporate and absorb heat, and absorb the low-grade heat energy from the outside world (which can be rivers, lakes, groundwater, underground soil layers, air, etc., which we call water source, ground source, and air source heat pump), and finally the evaporator comes out. The low pressure gas enters the compressor to complete the cycle.
Heating and Cooling Heat Pump is an evolved product of air conditioners. An electromagnetic four-way valve (also known as a reversing valve) is installed in the refrigeration system. Through the switching direction of the four-way valve, the flow direction of the refrigerant is changed, and the air conditioner can hot. The high-temperature and high-pressure vapor-like refrigerant discharged from the compressor flows to the condenser in the heat preservation water tank, transfers heat to the tap water passing through the water tank, and then throttles and reduces the pressure through the expansion valve, and evaporates and absorbs heat in the evaporator of the main outdoor heat pump group. Use the working fluid to absorb the heat in the outdoor air. The Heating and Cooling Heat Pump absorbs the heat in the outdoor air and transfers it to the tap water in the insulated water tank. It is more energy-saving, fast and safe than simply heating with an electric heater, and the outdoor thermal energy potential is infinite.
Noise problem, almost all of today's Heating and Cooling Heat Pumps use full frequency conversion technology, indoor unit frequency conversion, heat pump host frequency conversion, fan frequency conversion, etc. The noise value of the heat pump host is below 45 decibels, and the indoor noise is still below 20 decibels. Neither users nor neighbors will be affected.
JNOD has a complete heat pump industry chain, and its products involve Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer, etc. The ultra-low temperature EVI heat pump has been widely used, too.