Swimming Pool heat pumps are one of the most cost efficient heating options on the market. The start-up costs can be somewhat expensive but they are highly energy efficient while offering advanced heating technology. Swimming Pool heat pumps pay for themselves after just a couple of seasons via the savings you'll see on your utility bills.
Swimming Pool Heat Pump Benefits
Reliable and durable heat pumps require fewer repairs than gas heaters.
No emissions and low electrical use make heat pumps the eco-friendly pool heater.
Heats for much lower costs, costing 50-75% less than gas heaters to operate.
How Swimming Pool Heat Pumps Work:Swimming Pool heat pumps leverage a combination of air and electricity to heat your pool water. They use electricity to power a fan and a small compressor, to absorb surrounding air heat and transfer it into your pool’s water. Pool heat pumps require very little electricity to run.
Swimming Pool Heat Pump Installation: Heat pumps can be purchased, placed level and plumbed after the filter by any handy homeowner, but we recommend an electrician to come in for the power hook-up.
Swimming Pool Heat Pump Operation Cost: The cost to operate a heat pump depends on many factors such as size of Swimming pool, size of heat pump and the outside air temperature. When the air temperatures are colder, the fan and compressor must run longer to maintain temperature, but during warmer periods the heat pump may need to run only an hour per day to maintain water temperature.
For the swimming pool heat pump, we have both R32 and R410A model. The heating capacity can be made from 3KW to 97.5KW. ON/OFF and inverter model,residetial and commercial are available. It’s with 4 ways valve,provide both heating and cooling mode to create more possibility for pool enjoyment.
If you want to know more information, please feel free to contact us.
As heat pumps are more and more popular in the market, people want to know if it's worthy to use it.
Of course Yes! Heat pump water heaters are worth the cost.
More Efficient
Heat pumps are significantly more energy efficient than normal electric or gas hot water heaters because instead of using energy to generate new heat, they collect existing ambient warmth and transfer it to the water. This efficiency can save you hundreds of dollars on energy bills each year.
Tax Incentives and Rebates
With tax incentives and state-sponsored sales rebates, energy efficient heat pump water heaters can actually be a more affordable choice than most homeowners would expect. Though the upfront cost is high, most homeowners pay back heat pump water heaters within the first or second year alone. And heat pump water heaters are long-lasting – a good, well-maintained heater can last between ten to fifteen years.
Environmentally Friendly
Because heat pumps are more energy efficient than conventional hot water heaters, they do not use as much electricity and/or natural gas, which reduces greenhouse gas emissions. In fact, it estimates that if all residential water heaters were replaced with heat pump water heaters, there would be up to 140 billion pounds of greenhouse gas emissions are saved annually.
We Jnod now provide various air to water heat pump, any question or need welcome to inquire us!
Our website:https://www.jnodheatpump.com
JNOD has a complete heat pump industry chain, and its products involves Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer,etc.The ultra-low temperature EVI heat pump has been widely used, too.
The inverter technology is considered a perfect solution when it comes to energy-efficiency and economical operation. In an inverter model from a heat pump inverter manufacturer, the cooling and heating are automated in an energy-efficient and seamless manner whereas earlier technologies used to consume a lot of electricity irrespective of the required usage.This will be good to cut-off your electricity bill.
The compressor motor used by DC inverter heat pump manufacturer does not turn on and off all the time but keeps working at low power. This kind of machine makes the operation more quite.
Unlike non-inverters, they don't automatically turn on and off every time they reach a certain temperature; instead, they just cruise along maintaining and regulating the temperature constantly.
The technology and hardware employed in DC inverter model by DC inverter heat pump supplier not only makes the cooling and heating effect more efficient, but also makes the unit last longer. Contrary to the operation of a non-inverter unit, the inverter uses less power and as a result, they work less, meaning that they are less prone to wear and tear.
The DC inverter heat pump is able to cool and heat your room faster than its non-inverter counterpart. This is due to the fact that an inverter heat pump unit operates on a variable speed compressor rather than at a fixed speed one. This process ensures rapid air conditioning effects via faster variable speed allowing the compressor to run at full power only when required while constantly regulating the temperature as per end user's desire.
A smart DC Inverter heat pump will provide you complete control over energy consumption and usage through your PC and portable smart devices. Moreover, it will give you complete insights about all technical metrics such as watts, voltages, current and units consumed. A smart heat pump also lets the user schedule the heat pump to automatically turn itself on or off. Operations of a heat pump are more flexible and centralized when it is smart.
Please feel free to contact our JNOD sales team when you get more information.
The heat pump water heaterabsorbs the low-temperature heat in the air, vaporizes the cold medium, and then compresses it through the compressor to increase the temperature, and then converts it through the heat exchanger to heat the water, and the compressed high-temperature heat energy is used to heat the water temperature.
What is the difference between a heat pump water heater and an air conditioner?
What are the advantages of heat pump water heater and compared with gas water heater?
What are the advantages of heat pump water heater compared to electric water heater?
When a general air conditioner is refrigerating, it absorbs the heat in the room through the phase change of the refrigerant in the evaporator (liquid to gas), and then realizes cooling through the heat release of the outdoor condenser. His heat exchange equipment is mainly finned heat exchangers. The heat pump water heater converts the low-grade energy in the air into high-grade energy that we can use. The heat is obtained by absorbing heat from the air through the phase change (endothermic) of the refrigerant in the evaporator, and then releasing heat through the indoor condenser (or jacket heat exchanger). This is his heating state. Its cooling is the same as that of general air conditioners, except that the heat exchanger may be different. General air conditioners use ordinary finned heat exchangers.
Gas water heaters heat the water temperature by burning combustible gas, and at the same time, will produce greenhouse gases such as carbon dioxide. If the continuous large amount of carbon dioxide on the earth exists in the air for a long time, it will produce a greenhouse effect on the earth's environment! The heat pump water heater only heats the water temperature with the heat in the air, and will not emit any toxic and harmful gases. In the era of energy saving and emission reduction, it is a water heater that is truly energy-saving and environmentally friendly. Secondly, gas water heaters may leak gas and cause human carbon monoxide poisoning accidents. Therefore, the safety of empty heat pump water heater is better than that of gas water heater.
We can compare heat pump water heater with electric water heater. Electric water heaters are heated with electric heating rods. The heat pump water heater heats the water temperature by absorbing heat from the air. The heat generated by the heat pump water heater consumes 1 kWh of electricity equivalent to the heat generated by the electric water heater consuming 4 kWh of electricity. In terms of energy saving, heat pump water heaters are far more energy efficient than electric water heaters. Second, in terms of security. The heat pump water heater just transfers the heat after compression heating to the water tank for heating, so the water and electricity are completely isolated. The electric water heater electric heating rod is directly heated in the water. Therefore, leakage accidents are easy to occur!
Guangdong JNOD New Energy Technology Co., LTD. is committed to providing customers the best hot water & heating solutions with our heat pump products, focusing on the latest technologies, strive for outstanding quality in our products and customer service.
The working principle of the Heating and Cooling Heat Pump is a mechanical device that forces heat to flow from a low temperature object to a high temperature object in a reverse cycle. The applied low-grade thermal energy is utilized to achieve the purpose of energy saving.
How does the Heating and Cooling Heat Pump perform cooling and heating respectively?
What is the principle of Heating and Cooling Heat Pump?
Why is Heating and Cooling Heat Pump so practical?
When the air conditioner cools down in summer, the Heating and Cooling Heat Pump operates according to the cooling condition, and the high-pressure steam discharged from the compressor enters the condenser through the reversing valve (also known as the four-way valve); when heating in winter, the reversing valve Turn to the working position of the heat pump, so the high-pressure refrigerant vapor discharged from the compressor flows into the indoor evaporator (used as a condenser) after passing through the reversing valve, and the latent heat released when the refrigerant vapor condenses heats the indoor air to achieve indoor heating purposes. The condensed liquid refrigerant flows in the reverse direction through the throttling device into the condenser (used as an evaporator), absorbs external heat and evaporates, and the evaporated steam is sucked by the compressor after passing through the reversing valve to complete the heating cycle. In this way, the Heating and Cooling Heat Pump "pumps" the heat from the outside air (or circulating water) into the room with a higher temperature, so it is called a "heat pump"
When the air conditioner cools down in summer, it operates according to the refrigeration condition. The high-pressure steam discharged from the compressor by the Heating and Cooling Heat Pump enters the condenser through the reversing valve (also known as the four-way valve), and the refrigerant vapor is condensed into liquid. The flow device enters the evaporator, absorbs heat in the evaporator, cools the indoor air, and the evaporated refrigerant vapor is sucked by the compressor after passing through the reversing valve, and this cycle is repeated to realize the refrigeration cycle.
Heating and Cooling Heat Pump can operate normally between -27℃-48℃, and some low-temperature air-energy heat pumps are also capable of -35℃ ambient temperature, and still maintain normal operation. In our environment, a It can be used all-weather all year round, and will not be affected too much by rainy, windy and snowy weather, nor will it be affected by low temperature at night. However, solar heating equipment is greatly affected by environmental factors. In the case of insufficient light, it is difficult to achieve the effect of indoor heating, especially in areas with low ambient temperature in winter.
Guangdong JNOD New Energy Technology Co., LTD. provided marketing consultancy services and business solutions for customers from over 40 countries. tailor-make solution of hot water supply base on customer's market demand.
The heat pump water heater absorbs air energy through the compressor, releases heat through the refrigerant and then heats the hot water. In general, it is a purely electric or boiler fuel, and the air source is supposed to transfer the energy of the air to the water through a certain amount of electrical energy. It is cost effective and has low operating cost. That's the most important thing. heat pump water heaters are safer, more energy-saving, more environmentally friendly, safer and fashionable than ordinary water heaters.
What is the basic working principle of a heat pump water heater?
What are the advantages of heat pump water heater and solar water heater?
Heating and cooling heat pump can be connected to Wi-Fi?
Heat pump water heater mainly consists of compressor, heat exchanger, axial fan, water tank for heat preservation, water pump, liquid storage, filter, electronic expansion valve and electronic automatic control. After switching on the power supply, the axial fan starts running, the outside air flows through the evaporator for heat exchange, and the reduced temperature air is expelled from the system by the fan. A kind of low pressure working medium gas is compressed into high temperature and high pressure gas and fed to the capacitor. The water forcibly circulated by the water pump also passes through the condenser and is heated by the working medium and fed to the consumer for use. The working medium is cooled to a liquid and the liquid expands. After the valve is throttled and cooled, it flows back into the evaporator. This cycle works repeatedly, and the heat energy in the air is continuously "pumped" into the water, so that the water temperature in the water tank for heat preservation gradually rises and finally reaches about 55°C, which is just suitable for people to take a bath.
Both work with air and solar energy, two of nature's renewable energy sources. What's the difference between the two?
In all seasons, even in winter, the effect of solar water heaters is very clear with sufficient sunlight, as well as on long rainy, snow and cloudy days. Solar water heaters cannot reflect the heating effect. The heat pump water heater is not affected by weather and season. It can supply hot water to users at any time. To be clear: The air flow heater can have hot water where there is air!
Wifi Monoblock High performance heat pump for heating and cooling, we offer not only advanced energy efficient heat pumps with advanced inverter technology, but also a total solution for heating, cooling and hot water supply in private homes. It has the WiFi remote. The heating and cooling heat pump can be controlled via Wi-Fi, allowing users to operate their heat pumps anytime, anywhere.
Guangdong JNOD New Energy Technology Co., LTD. can manufacture standard products under customers' brand, modify the products to meet customers' personalized requirements, and cooperate with customers to design and manufacture completely new products.
In recent years, the potential energy of the sports industry under the national fitness, and favorable policies such as swimming into the high school entrance examination sports, the constant temperature swimming pool was once in short supply, and the Swimming Pool Heat Pump was out of stock.
What is the first stage of the workflow of Swimming Pool Heat Pump?
What is the second stage of the workflow of Swimming Pool Heat Pump?
What should we pay attention to when using Swimming Pool Heat Pump?
In the first step, the indoor hot and humid air in the swimming pool first exchanges heat with the outdoor fresh air through the heat exchanger to become warm and humid air, and then the warm and humid air flows through the evaporator, the temperature drops, and the water vapor condenses into cold water droplets and is separated from the air. Make the air dry and realize the function of air dehumidification; at the same time, the heat energy (latent heat and sensible heat) is released in the process of air cooling, water vapor condensation and cooling are absorbed by the refrigerant.
In the second step, the heat energy absorbed by the refrigerant first (latent heat) heats the pool water through the heat exchanger to realize the pool water heating function: the residual heat (sensible heat) passes through the air condenser to heat the cooled indoor air to realize the air insulation function. In the severely cold winter, when the energy available for the heat pump to extract in the air is too small, and the heat energy recovered by the heat pump is not enough to meet the requirements of the indoor air temperature, the auxiliary air heater is added to supplement the heat energy required for the indoor hot air. The Swimming Pool Heat Pump only needs to provide its own operating power, that is, it runs continuously according to the above working procedures, and achieves a harmonious balance of the three functions of pool water heating, air conditioning and dehumidification with low energy consumption.
1. When maintaining and cleaning the Swimming Pool Heat Pump, make sure that the Swimming Pool Heat Pump is in a power-off state. In addition, when the heat pump is not in use: the power supply should also be cut off.
2. Do not use gasoline, Tianna water, volatile oil, solvents and other chemicals, or liquid pesticides on the Swimming Pool Heat Pump, otherwise it may cause parts to crack and deform.
3. The area around the Swimming Pool Heat Pump should be kept dry and well ventilated.
4. Regularly clean the air-side heat exchanger to maintain a good heat exchange effect. If the shutdown time is long, the water in the pipeline of the unit should be drained, the power supply should be cut off, and the protective cover should be put on. When it is necessary to use it again, the system must be thoroughly checked before turning it on.
After reading, do you have a deeper understanding of Swimming Pool Heat Pump? For further information, please contact Guangdong JNOD New Energy Technology Co., LTD. They will be very pleased to help you.