When the indoor swimming pool is used in winter, it is necessary to heat the pool water to make the water temperature reach 26-28 degrees, which requires a lot of thermal energy. Boilers, gas, and electricity are gradually eliminated due to their low thermal efficiency and environmental protection. More and more people will Option to use Swimming Pool Heat Pump. So in addition to environmental protection, what are the benefits of Swimming Pool Heat Pump?
Compared with traditional boilers, what are the advantages of Swimming Pool Heat Pump?
What advancements have the Swimming Pool Heat Pump made?
Why is the demand for Swimming Pool Heat Pump increasing?
Compared with traditional boilers, Swimming Pool Heat Pump does not use any fuel such as coal, oil, gas, etc., and does not produce open flames and exhaust emissions. Therefore, the use of air source heat pumps not only protects the atmospheric environment, but also eliminates fire, explosion, poisoning, etc. Accident happens. Compared with ordinary electric water heaters, it consumes less power, avoids leakage accidents, saves energy and is environmentally friendly. Compared with solar water heaters, air energy heat pumps are not affected by weather, geography, climate and other factors when working Sunny can be used normally.
smart system
① The unit control system adopts intelligent control. When customers use it, they only need to set the air temperature, humidity, and pool water temperature, and then the equipment will enter the fully automatic operation state, and there is no need for special personnel to take care of it.
② Customers can learn air temperature, humidity and other data through the touch-type full-color screen. Real-time value of pool water temperature and operating status of equipment.
③ Customers can also choose a communication interface according to their needs to implement remote control, monitoring and connection with the system.
ventilation system
Customers can choose the intelligent ventilation system of Swimming Pool Heat Pump. After choosing this system, the unit will control the amount of fresh air entering the room according to the concentration of carbon dioxide in the room, which can greatly save the energy consumption during operation.
Not only that, the advancement and development of sports equipment and facilities and equipment technology have also provided a foundation for more people to actively participate in fitness. Take swimming, the most popular sport, as an example. In the past, people swimming in open-air pools or public waters were easily limited by the temperature environment. If they accidentally caught a cold, it would be bad for their health, and microbial bacteria would grow in public waters. , the health situation is not optimistic. In recent years, with the advancement of Swimming Pool Heat Pump related supporting technical facilities, many swimming pools and other fitness places are equipped with heated swimming pools, and even schools, communities, villas, etc. are equipped with heated swimming pools, so that people can not only enjoy the hot summer. The fun of refreshing swimming can also have a comfortable swimming experience in the cold winter.
If you would like to receive more information about the Swimming Pool Heat Pump, please connect Guangdong JNOD New Energy Technology Co., LTD., and they will be happy to answer your question!
Heat pump water heater is a new type of water heater. It converts air energy into heat energy through a heat pump to produce hot water. This water heater solves the disadvantage that solar energy cannot be used on rainy days. In addition, this water heater is more efficient compared to gas water heaters and electric water heaters. Environmental protection when you choose this water heater is a very good choice.
What is the main reason why air heat pump water heaters are popular in the market?
What is the workflow of a heat pump water heater?
What do you know about heat pump water heaters that can be used in hotels?
Air Source Water Heater is a new type of low carbon and environmentally friendly water heater. The operating cost of heat pump water heaters is only 1/4 of the cost of electric water heaters, which is very energy-saving and efficient. Originally, as a fourth-generation air water heater, its greatest feature is safety and money-saving! The operating costs of the air water heater are only 1/4 of the electric water heater, 1/6 of the gas water heater, 1/2 of the solar water heater, 2/3 of the fuel water heater and 3/5 of the gas heating system. The device absorbs the heat in the air to heat the cold water, and the cool air released does not pollute the environment and completely eliminates the safety risks such as flammability, explosion, electric shock and gas poisoning of ordinary water heaters.
1. The compressor compresses the low pressure refrigerant flowing back and converts it into a gas with high temperature and high pressure for discharge.
2. The high temperature and high pressure refrigerant gas flows through the copper pipe wrapped around the outside of the water tank, and the heat is passed through the copper pipe into the water tank. The cooled refrigerant becomes liquid under constant pressure and enters the evaporator after passing the expansion valve.
3. As the pressure of the evaporator is suddenly reduced, the liquid refrigerant is quickly evaporated into a gaseous state and absorbs a large amount of heat.
4. At the same time, under the action of the fan, a large amount of air flows through the outer surface of the evaporator, the energy in the air is absorbed by the evaporator, the air temperature drops quickly, and cold air is released and released.
5. The refrigerant that has absorbed a certain amount of energy is then returned to the compressor and enters the next circuit.
JNOD hot water heat pumps provide a highly efficient means of heating hot water for commercial and industrial applications. An average COP of 4.2 means that the energy efficiency is more than four times higher than that of conventional water heaters. It removes heat energy from the ambient air. This means savings of 60.75% of energy costs compared to electric water heaters.
Guangdong JNOD New Energy Technology Co., LTD. Provides marketing consulting services and business solutions to customers from over 40 countries. Customized solution for hot water supply based on the customer's market demand.
Heat pump water heatersare "heat transfer" devices that use the principle of refrigeration to absorb heat from the air to heat water. A refrigerant with a boiling point of more than minus 10°C is passed into the exchanger, and the refrigerant absorbs heat from the air by evaporating from liquid to gas.
What is the safety of the use of heat pump water heaters?
What is the output of the heat pump water heater?
Where is the convenience of heat pump water heater?
The heat pump water heater does not require sunlight, so it can be placed at home or outdoors. After the water stored in the solar water heater is used up, it is difficult to produce hot water immediately. If the electric heating takes a long time, as long as there is air and the temperature is above minus 20 degrees Celsius, the heat pump water heater can be under pressure 24 hours a day. run. In this way, even if one tank of water is used up, the air source water heater will produce another tank of hot water in about an hour or even less time. At the same time, the heat pump water heater can also fundamentally eliminate the safety hazards such as electric water heater leakage, dry burning and harmful gas generated when the gas water heater is used.
The water output is large. The water tank capacity of the heat pump water heater is between 150L-760L. Users can choose the corresponding capacity of the air energy water heater according to the needs of the family. Water, bath water, etc., truly realize the central hot water for the whole family and improve the quality of life of users. But be aware that heating at extremely low temperatures with a heat pump water heater is more difficult and may waste electricity, and the water tank needs to take up the heating space.
Long life
The life of heat pump water heater is generally 10 years (here for reference), which is longer than 6 years for gas water heaters and 8 years for electric water heaters. The advantages of air source water heater life can reduce the frequency of replacement water heaters, the trouble of installation, and save a lot of money.
Central hot water
Consumers often need hot water in their daily lives, but without hot water sources, they usually boil a pot of water for use. The heat pump water heater has a central hot water function. It stores the heated water in the heat preservation water tank, and there is a comfortable and constant temperature hot water as long as you press the tap. The hot water of the air energy water heater can be used in the whole family, fully meeting the domestic hot water demand of consumers.
Guangdong JNOD New Energy Technology Co., LTD. has focused on the field of heat pump water heaters for many years, it has attracted a large number of consumers around the world with its high-quality products, appropriate prices, and excellent services.
Compared with the traditional swimming pool heating method, the biggest advantage of Swimming Pool Heat Pump is that it can effectively improve the heating speed and constant temperature of the swimming pool, making the swimming pool water heating safer, more energy-saving and faster, so as to meet the different heating temperature requirements of the swimming pool.
Is the Swimming Pool Heat Pump safe to use?
What are the application advantages of Swimming Pool Heat Pump?
What are the benefits for consumers of the application of Swimming Pool Heat Pump?
Swimming Pool Heat Pump relies on the "reverse Carnot" principle to work, using clean and renewable raw materials (air energy + electricity) as energy, neither generating harmful gases to the human body nor causing pollution to the atmosphere. With only a small amount of electricity input, a large amount of heating benefits can be obtained, providing a 24-hour constant temperature for the swimming pool.
From the perspective of energy saving and safety, Swimming Pool Heat Pump is an ideal choice for indoor swimming pool heating equipment. It is powerful, stable and efficient. It adopts high-efficiency titanium bubble heat exchanger, which has high efficiency, corrosion resistance and ultra-high energy efficiency. Refrigeration accessories, high operating efficiency and energy saving. And it is safe and reliable, water and electricity are completely separated; it can also intelligently control, realize independent temperature control, intelligent defrosting, etc. It is widely used in various swimming pools, hotel swimming pools, SPA, hot springs, bubble pools, etc., and it is easy to use.
Swimming Pool Heat Pumpdoes not discharge any pollutants during operation, and there are no safety hazards such as fire, explosion, poisoning, etc., which is very safe and environmentally friendly. As a professional swimming pool constant temperature equipment, Tongyi Air Energy swimming pool special constant temperature heat pump is equipped with a triple disinfection filter protection system, which can automatically complete disinfection, adjust pH value, and collect tiny dirt and suspended particles (such as dandruff, dust, etc. in swimming pool water) ), hair and other pollutants, not only to ensure the cleanliness of the swimming pool water, but also to protect the normal operation of subsequent equipment, effectively reducing the workload of the staff. For swimming pool operators, Swimming Pool Heat Pump saves more than 65% of operating costs compared to hot water equipment using other energy sources, and the unit is fully automatic and intelligent, which greatly reduces labor costs.
The Swimming Pool Heat Pump keeps the indoor heated swimming pool at a constant temperature of 26-28 degrees. Normal swimming pools use cold water. Due to the low water temperature (0-10 degrees in winter, 10-20 degrees in summer), not many people can swim in cold water, especially children, the possibility of catching a cold is very high. The constant temperature swimming pool is heated by heating equipment and maintains a temperature of 26-28 degrees throughout the year, which is suitable for the human body and allows you to say goodbye to the risk of swimming colds.
Guangdong JNOD New Energy Technology Co., LTD. focuses on heat pump& electric boiler R&D, manufacturing and providing comprehensive energy-saving solutions.
JNOD are selling R32 inverter swimming pool heat pump, its heating capacity ranges from 5.5-32Kw. So, it will be a problem for user or wholesaler to choose the suitable heating capacity for different pool sizes. Let us show you 2 methods to choose the suitable.
If you do not want to do complicated calculations and do not take into account extreme weather, you can use the following formula: 3KW for 10m³. For example, if you want to heat a 30CBM pool, (30 CBM÷10CBM)* 3KW = 9KW . So, you can choose the 9.5Kw model.
This method is used to do a very precise calculation on the heating capacity, considering the heating time, water temperature, ambient temperature, etc.
* Step 1: Calculate the needed heating capacity
In the calculation, we usually set the outlet water temperature at 28℃, primary heating time usually is 48hours.
Formula will use: Q=1.163*△t*V ;
W=Q/T
Explanation: Q = Heat Demand (KwH)
△t = Temperature Difference (℃)
V = volume of pool (m³)
W = Heat pump capacity(Kw) - usually will add 15-25% of heat loss
T = Hours for heating (H)
Example: A swimming pool 10*4*1.5m, original temperature is 18℃
Answer: set the target temperature into 28℃, heating hour into 48 hours
Q = 1.163*(28-18)*(10*4*1.5)=697.8 KwH
W= (1+15%) *Q/T=1.15*697.8/48=16.72 KW
*Step 2 : Choose the suitable heating capacity depending on working condition
The heating capacity of a heat pump is not constant; it changes with the ambient temperature. Therefore, after calculating the required heating capacity, we also need to choose the model we need according to the ambient temperature.
Still that sample, we calculate that 16.72Kw is needed. If the ambient temperature is around 24-27℃, you can choose the 17.5Kw model; if ambient temp is around 12-15℃, better to choose 25kw model.
Model | J175P32INVP | J210SP32INVP | J250SP32INVP |
Ambient Temperature:(DB/WB)27℃/24.3℃ | |||
Heating Capacity (kW) | 4.34~18.1 | 4.72~21.21 | 5.05~25.28 |
Power Input (kW) | 0.27~2.81 | 0.29~3.26 | 0.31~3.89 |
COP | 16.1~6.4 | 16.2~6.5 | 16.2~6.5 |
Ambient Temperature:(DB/WB)15℃/12℃; | |||
Heating Capacity (kW) | 3.44~13.35 | 3.51~14.21 | 3.81~17.08 |
Power Input (kW) | 0.41~2.61 | 0.43~2.78 | 0.48~3.35 |
COP | 8.3~5.1 | 8.1~5.1 | 8~5.1 |
Hope this can help you choose suitable models for swimming pool.
Any question or idea please don’t hesitate to inquire JNOD!
Heating and Cooling Heat Pump uses scientific methods to make low-temperature heat energy flow to high-temperature heat energy according to the "inverse Carnot principle", and obtains more heat energy from the air, which has wide adaptability.
How does the Heating and Cooling Heat Pump cycle for cooling and heating?
What is the principle of Heating and Cooling Heat Pump?
Can the Heating and Cooling Heat Pump still operate at an ambient temperature of 0°C?
During heating, the refrigerant (environmentally friendly refrigerant) in the Heating and Cooling Heat Pump host will absorb the low-temperature heat energy in the air through the evaporator, and then convert it into high-temperature heat energy through the compressor, and then transfer the heat energy to the heating circulating water through the heat exchanger. Finally, the heated hot water is transported to the indoor heating terminal for heat dissipation through the water pump, and then returned to the heat exchanger for heating after the heat dissipation, and the process is repeated.
During cooling, the cycle of the Heating and Cooling Heat Pump system is just the opposite, absorbing the indoor heat and transferring it to the outdoors. Air heat exchange, an additional heat exchange program.
Shallow water sources on the earth's surface (generally within 1000 meters), such as groundwater, surface rivers, lakes and oceans, absorb considerable radiant energy from the sun into the earth, and the temperature of water sources is generally very stable. The working principle of Heating and Cooling Heat Pump is to realize the transfer of low-temperature heat to high-temperature by inputting a small amount of high-grade energy (such as electric energy). The water body is used as the heat source of heat pump heating in winter and the cold source of air conditioning in summer, that is, the heat in the building is "taken out" and released into the water body in summer. Because the water source temperature is low, it can efficiently take away the heat, so as to achieve the purpose of indoor cooling of the building in summer; In winter, heat energy is "extracted" from the water source and sent to the building for heating through Heating and Cooling Heat Pump.
The answer is yes, although Heating and Cooling Heat Pumpproducts were mostly used in high temperature areas in the early days, with the continuous development of heat pump technology, air energy heat pump heating can be used in most areas, especially for some low temperature environments. The Heating and Cooling Heat Pump uses technologies such as jet enthalpy to ensure that the Heating and Cooling Heat Pump can operate normally in severe cold climates.
Guangdong JNOD New Energy Technology Co., LTD. has been committed to providing customers with Heating and Cooling Heat Pumps and perfect after-sales service so that customers can invest easily, use them with confidence, and have no worries.
Air source heat pump water heaters have the characteristics of high efficiency and energy saving. Its energy saving effect is 4 times that of electric water heaters, 3 times that of gas water heaters, and about 2 times that of solar water heaters.
Is there a difference between an air source heat pump water heater and a normal water heater?
What are the environmental protection features of heat pump water heaters?
How does the heat pump water heater work?
Environmental protection, the heat pump water heater realizes that there is hot water whenever you want. Because it does not use electric heating elements for direct heating, compared with electric water heaters, it eliminates the potential safety hazard of electric leakage; compared with gas water heaters, there is no gas leakage, or Safety hazards such as carbon monoxide poisoning, so it has better safety performance. The air energy heat pump is regenerative, and the heating function is automatically activated according to the temperature in the water tank to ensure sufficient supply of hot water for 24 hours, so there is no such problem as the gas water heater that cannot meet the hot water for multiple faucets at the same time, nor will it There is a problem that the capacity of the electric water heater is small, and many people need to wait for a bath. The hot water is ready to use, the water output is large, and the water temperature is stable, meeting all your expectations for hot water. Because its power consumption is only one-fourth of the same amount of electric water heater, which is equivalent to using the same amount of hot water, using an air-energy heat pump, the electricity bill is only one-fourth of that of electric heating. Calculated for a family of 4, the normal consumption of hot water is about 200l/day. Electric water heaters cost about 4 yuan/day for heating, while heat pump water heaters only cost about 1 yuan/day, saving 1,000 yuan a year.
Environmental protection of heat pump water heaters: using clean energy, no waste gas, waste water, waste residue, and no thermal effect on the air. The use of environmentally friendly heat medium, cfc-free, will not cause damage to the atmospheric ozone layer. Uses of heat pump water heaters: heat pump water heaters can be used in hot water systems with a temperature requirement lower than 65°C, such as bathing, sauna, swimming pool, foot bath, beauty salon, agricultural breeding, etc. The heat pump water heater has a high energy efficiency ratio and is more energy-saving.
A heat pump water heater is essentially a heat lifting device. The function of the heat pump is to absorb heat from the surrounding environment and transfer it to the object being heated (a higher temperature object). Its working principle is the same as that of a refrigerator. It works according to the reversed Carnot cycle, the only difference is that the working temperature range is different.
Guangdong JNOD New Energy Technology Co., LTD. has been a Chinese pioneer in heat pump water heater for several years. They can provide any type of heat pump water heaters you need. At the same time, their after-sales service is also very considerate.
JNOD are selling R32 inverter swimming pool heat pump, its heating capacity ranges from 5.5-32Kw. So, it will be a problem for user or wholesaler to choose the suitable heating capacity for different pool sizes. Let us show you 2 methods to choose the suitable.
If you do not want to do complicated calculations and do not take into account extreme weather, you can use the following formula: 3KW for 10m³. For example, if you want to heat a 30CBM pool, (30 CBM÷10CBM)* 3KW = 9KW . So, you can choose the 9.5Kw model.
This method is used to do a very precise calculation on the heating capacity, considering the heating time, water temperature, ambient temperature, etc.
* Step 1: Calculate the needed heating capacity
In the calculation, we usually set the outlet water temperature at 28℃, primary heating time usually is 48hours.
Formula will use: Q=1.163*△t*V ;
W=Q/T
Explanation: Q = Heat Demand (KwH)
△t = Temperature Difference (℃)
V = volume of pool (m³)
W = Heat pump capacity(Kw) - usually will add 15-25% of heat loss
T = Hours for heating (H)
Example: A swimming pool 10*4*1.5m, original temperature is 18℃
Answer: set the target temperature into 28℃, heating hour into 48 hours
Q = 1.163*(28-18)*(10*4*1.5)=697.8 KwH
W= (1+15%) *Q/T=1.15*697.8/48=16.72 KW
*Step 2 : Choose the suitable heating capacity depending on working condition
The heating capacity of a heat pump is not constant; it changes with the ambient temperature. Therefore, after calculating the required heating capacity, we also need to choose the model we need according to the ambient temperature.
Still that sample, we calculate that 16.72Kw is needed. If the ambient temperature is around 24-27℃, you can choose the 17.5Kw model; if ambient temp is around 12-15℃, better to choose 25kw model.
Model | J175P32INVP | J210SP32INVP | J250SP32INVP |
Ambient Temperature:(DB/WB)27℃/24.3℃ | |||
Heating Capacity (kW) | 4.34~18.1 | 4.72~21.21 | 5.05~25.28 |
Power Input (kW) | 0.27~2.81 | 0.29~3.26 | 0.31~3.89 |
COP | 16.1~6.4 | 16.2~6.5 | 16.2~6.5 |
Ambient Temperature:(DB/WB)15℃/12℃; | |||
Heating Capacity (kW) | 3.44~13.35 | 3.51~14.21 | 3.81~17.08 |
Power Input (kW) | 0.41~2.61 | 0.43~2.78 | 0.48~3.35 |
COP | 8.3~5.1 | 8.1~5.1 | 8~5.1 |
Hope this can help you choose suitable models for swimming pool.
Any question or idea please don’t hesitate to inquire JNOD!
Under normal circumstances, when the average temperature is -5°C, the Heating and Cooling Heat Pump can generate more than three times the amount of heat per kWh of electricity consumed, and the energy saving efficiency is as high as 75% compared to the direct conversion of electrical energy into heat; when the average temperature is - At 15°C, 1 kWh of electricity consumption can generate more than twice the heat; even at -25°C, the Heating and Cooling Heat Pump can normally provide heat for the room.
What are the similarities and differences between Heating and Cooling Heat Pump and solar water heaters?
What is PTC heating with Heating and Cooling Heat Pump?
What are the advantages of using the Heating and Cooling Heat Pump?
From the scope of application, heating continuity, operating cost, and installation conditions, Heating and Cooling Heat Pumpis easier to popularize than solar heating equipment, and solar heating equipment will be more affected by environmental factors. At the same time, the thermal efficiency of Heating and Cooling Heat Pump is very high, consuming 1 kWh of electricity can get three heat energy, and even if the thermal efficiency of solar energy reaches 100%, consuming 1 kWh of electricity can only generate 1 heat energy. It can be seen that the public is most concerned about energy saving. When the environment is harsh in winter, the energy consumption of Heating and Cooling Heat Pump is lower than that of solar heating equipment.
PTC electric heater is a kind of heater with automatic temperature control and power saving. It uses PTC heat-sensitive ceramic element as heating source, corrugated sheet made of aluminum alloy as radiator, and the heater is composed of bonding and welding. . Electric vehicle air-conditioning heater PTC generally collects data from temperature sensors through the air-conditioning controller, and adjusts the output power to achieve temperature setting. Currently widely used in pure electric vehicles. However, when the Heating and Cooling Heat Pump is used for heating in winter, the power consumption of the battery is very large, which seriously affects the cruising range. Now they have turned their attention to the heat pump solution, or the parallel solution of the two.
First, energy saving is beneficial to the comprehensive utilization of energy. Heating and Cooling Heat Pump absorbs the low temperature heat energy in the air, and converts it into high temperature heat energy after being compressed by the compressor, and its energy saving effect is quite significant;
Second, Heating and Cooling Heat Pump is conducive to environmental protection;
Third, the combination of cold and heat, the application rate of Heating and Cooling Heat Pump is high, saving investment,
Fourth, because the Heating and Cooling Heat Pump is electrically driven, it is more convenient to control.
The Heating and Cooling Heat Pump has achieved an irreplaceable position in furniture design. Guangdong JNOD New Energy Technology Co., LTD. is committed to providing various Heating and Cooling Heat Pumps of high quality for all customers from all over the world.
The heating and cooling heat pump is a highly efficient, energy-saving device that makes full use of inferior thermal energy. Heat can be transferred spontaneously from a hot object to a cold object, but not spontaneously in the opposite direction.
How does the heating and cooling heat pump work?
What does the operating time of the heating and cooling heat pump have to do?
What is the function of the heating and cooling heat pump?
In the heating and cooling circuit of the heat pump, the heat Q0kcal/h is obtained from the low temperature heat source (outside air or circulating water whose temperature is higher than the evaporation temperature t0) and the mechanical work ALkcal/h is consumed, while the heat of Q0kcal/h is obtained from the low temperature heat source (outside air or circulating water whose temperature is higher than the evaporation temperature t0) and the mechanical work ALkcal/h is consumed. The heating system) provides the heat of Q1kcal/h, and the relationship between these heats corresponds to the first main law of thermodynamics, ie Q1=Q0+ALkcal/h
If the heating and cooling heat pump is not used and the heat is converted by mechanical work (or the high temperature heat source is heated directly by electrical energy, the heat obtained is ALkcal/h, and after the heat pump device is used, the high temperature heat source (heating system) receives more heat is obtained: Q1-AL=Q0, kcal/h This heat is obtained from a low temperature heat source, and this heat cannot be obtained without a heat pump device. Therefore, using a heat pump device can save fuel and use waste heat.
The working cycle of a heating and cooling heat pump is exactly the opposite of that of a thermal engine. A thermal engine uses the energy of a high-temperature heat source to generate mechanical work, while a heat pump transfers heat from a low-temperature heat source to a high-temperature object by consuming mechanical work.
If the heat pump and the heat engine have two identical heat source temperatures, the thermal efficiency of the heat engine cycle is η=AL/Q1; the energy index of the thermal engine cycle – the heat conversion coefficient φ=Q1/AL, i.e. φ=1/η. The value of η is always less than 1, so the value of φ is greater than 1.
If the refrigerator and the heat pump have two identical heat source temperatures, the relationship between them is φ=Q1/AL=(Q0+AL)/AL=e+1, where η is the refrigerator's cooling coefficient. It can be seen that the minimum value of the heat transfer coefficient φ η1 and in this limit case Q0 E0, that is, no heat is absorbed from the low temperature heat source.
Green simultaneous universal heat pump for heating and cooling
We offer not only advanced, energy-efficient heat pumps with advanced inverter technology, but also a complete solution for heating, cooling and hot water supply of residential buildings.
WiFi remote control
The heating and cooling heat pump can be controlled via Wi-Fi, allowing users to operate their heat pumps anytime, anywhere.
Three in one function mode
Hot water (DHW) + Heating and cooling.
Guangdong JNOD New Energy Technology Co., LTD. Focus on research and development of heat pumps and electric boilers, manufacturing and providing comprehensive energy saving solutions.
Heating and Cooling Heat Pump is a central air-conditioning unit that uses air as a cooling (heat) source and water as a circulating medium to transfer energy. Its advantages are that it is easy to install and use, and it can be used after connecting to the power supply, saving a complex cooling water system and a boiler heating system.
Compared with other products of the same type, why is Heating and Cooling Heat Pump cost-effective?
What are the common Heating and Cooling Heat Pumps on the market?
What to look for when choosing a Heating and Cooling Heat Pump?
Compared with electric boilers, Heating and Cooling Heat Pump can save more than 50% of power consumption, and reduce the trouble of frequent replacement of electric heating tubes; Compared with traditional coal boilers and oil-fired boilers, Heating and Cooling Heat Pump is pollution-free, emission-free, and safe , eliminating the need for annual routine security inspections, eliminating the need for professional boiler workers, fully automatic temperature control, and significantly reducing operating costs by more than 50%. Heating and Cooling Heat Pump completes a heat pump for heating and cooling needs in a particular field. Generally speaking, Heating and Cooling Heat Pump uses specialized heat pump compressors, special refrigerants and systems.
There are many types of heat pump water heaters on the market, mainly including three series of solar boost type, water source and air source. Solar-assisted heat pump is a heat pump technology that combines heat pump and solar energy technology; water source heat pump uses a certain temperature water source (above 20 ℃) as a heat source and uses refrigerant as a medium to absorb the heat in the water source and then compress it by a compressor. For heating, exchange heat with cold water through a heat exchanger to achieve the purpose of heating and producing hot water. The water source heat pump must have a water source with a certain temperature and flow; the air source heat pump obtains heat from the air in a similar way to the water source heat pump to heat water. Among the three types of heat pumps, the air source heat pump is subject to the least restriction and has the largest development space.
Whether the Heating and Cooling Heat Pump saves electricity has a lot to do with outdoor temperature, building insulation, user usage, equipment purchase and installation. If you want to save more electricity, users not only need to carefully select air source products, such as buying big brands as much as possible, finding professionally qualified installers for installation, etc., but also mastering the correct air source heat pump heating method, in order to achieve high efficiency and energy saving.
Guangdong JNOD New Energy Technology Co., LTD. has various Heating and Cooling Heat Pumps that can provide the increasing of products, and make them more effective, reliable, and consistent.
Water heating accounts for around 18% of the average home’s energy use. Switching to an energy-efficient heat pump water heater can make a difference on your utility bill and is an essential step in lowering the carbon footprint of your home.
We believe we JNOD are a very good heat pump supplier for you as following reason.
1. Complete Product Range:
JNOD has complete air to water heat pump product ranges, including heat pump water heaters, heating&cooling heat pump and swimming pool heat pump. We can satisfy most residential hot water and space heating need for apartment or single house.
2. Certification
Our All in one heat pump water heater gains the latest CE certificate and A+ ERP label. For some countries, distributor or install company can use them to apply the subsidies from government.
3. Multi-function
Regard to all in one hot water heat pump:
- If you look for hybrid hot water heat pump, choose the all in one heat pump. It’s a kind of electric + air source heat pump as there is an auxiliary electric heating inside as a backup.
- If there is a solar system, wires can directly connect to inverter, which can provide the electricity needed by heat pump, and then the need of grid can be reduced.
- If you want remote control, options like WiFi and RS485 can be provided.
4. OEM/ODM
If you have need of OEM/ODM, welcome to inquire us with the logo and design file you want, we will try our best to help you with better selling.
heating and cooling heat pump integrates air conditioning and heating systems, is comfortable and energy-saving, and will surely lead the market trend of comfortable home life in the future.
How exactly does the heating and cooling heat pump work?
What is the basic principle of heating and cooling heat pump?
Will the floor height affect the installation of the heating and cooling heat pump?
The common heating and cooling heat pumps on the market are almost all of combined cooling and heating, which solves the problems of cooling in summer and heating in winter through a set of equipment. In some specific areas (the temperature is relatively high in winter), the air energy heat pump can also be connected to the domestic hot water tank to provide 24-hour uninterrupted hot water for the family, so the air energy heat pump can be used for cooling and heating, as well as cooling and heating. And with domestic hot water, but in order not to affect the heating effect, the domestic hot water is generally not combined.
Basic principle of heating and cooling heat pump: it is mainly composed of compressor, heat exchanger, axial fan, thermal insulation water tank, water pump, liquid storage tank, filter, electronic expansion valve and electronic automatic controller. After the power is turned on, the axial flow fan starts to operate. The outdoor air is heat exchanged through the evaporator. The air with reduced temperature is discharged from the system by the fan. At the same time, the working medium inside the evaporator is sucked into the compressor. The compressor compresses the low-pressure working medium gas into high-temperature and high-pressure gas and sends it to the condenser. The water forcibly circulated by the water pump also passes through the condenser and is heated by the working medium and sent to the user for use, The working medium is cooled into liquid, which flows into the evaporator again after throttling and cooling by the expansion valve. In this way, the heat energy in the air is continuously "pumped" into the water, so that the water temperature in the insulation water tank gradually rises to about 55 ℃, which is just suitable for people to take a bath. This is the basic working principle of heating and cooling heat pump.
The floor height problem, many people think that the floor height of the elevator apartment is relatively low, and the installation of heating and cooling heat pump will cause the room to become depressed, but in fact, the installation of heating and cooling heat pump will not have much impact on the floor height. , The concealment of central air-conditioning can reduce the sense of oppression of the floor height through the reasonable planning of the ceiling, and the floor heating can also be laid by dry floor heating. The floor height is only increased by 3-4 cm, and the user cannot distinguish it with the naked eye.
Guangdong JNOD New Energy Technology Co., LTD. is the leading manufacturer sofa manufacturer specializing in heating and cooling heat pump. If you want to get more information, just go and connect them.
Air source heat pump water heaters have the characteristics of high efficiency and energy saving. Its energy saving effect is 4 times that of electric water heaters, 3 times that of gas water heaters, and about 2 times that of solar water heaters.
Is there a difference between an air source heat pump water heater and a normal water heater?
What are the environmental protection features of heat pump water heaters?
How does the heat pump water heater work?
Environmental protection, the heat pump water heater realizes that there is hot water whenever you want. Because it does not use electric heating elements for direct heating, compared with electric water heaters, it eliminates the potential safety hazard of electric leakage; compared with gas water heaters, there is no gas leakage, or Safety hazards such as carbon monoxide poisoning, so it has better safety performance. The air energy heat pump is regenerative, and the heating function is automatically activated according to the temperature in the water tank to ensure sufficient supply of hot water for 24 hours, so there is no such problem as the gas water heater that cannot meet the hot water for multiple faucets at the same time, nor will it There is a problem that the capacity of the electric water heater is small, and many people need to wait for a bath. The hot water is ready to use, the water output is large, and the water temperature is stable, meeting all your expectations for hot water. Because its power consumption is only one-fourth of the same amount of electric water heater, which is equivalent to using the same amount of hot water, using an air-energy heat pump, the electricity bill is only one-fourth of that of electric heating. Calculated for a family of 4, the normal consumption of hot water is about 200l/day. Electric water heaters cost about 4 yuan/day for heating, while heat pump water heaters only cost about 1 yuan/day, saving 1,000 yuan a year.
Environmental protection of heat pump water heaters: using clean energy, no waste gas, waste water, waste residue, and no thermal effect on the air. The use of environmentally friendly heat medium, cfc-free, will not cause damage to the atmospheric ozone layer. Uses of heat pump water heaters: heat pump water heaters can be used in hot water systems with a temperature requirement lower than 65°C, such as bathing, sauna, swimming pool, foot bath, beauty salon, agricultural breeding, etc. The heat pump water heater has a high energy efficiency ratio and is more energy-saving.
A heat pump water heater is essentially a heat lifting device. The function of the heat pump is to absorb heat from the surrounding environment and transfer it to the object being heated (a higher temperature object). Its working principle is the same as that of a refrigerator. It works according to the reversed Carnot cycle, the only difference is that the working temperature range is different.
Guangdong JNOD New Energy Technology Co., LTD. has been a Chinese pioneer in heat pump water heater for several years. They can provide any type of heat pump water heaters you need. At the same time, their after-sales service is also very considerate.
The basic principle and characteristics of Swimming Pool Heat Pump. It is based on the basic principle of the reversed Carnot cycle, using a small amount of electricity to drive a device that transfers heat from a low-temperature heat source to a high-temperature heat source.
What are the advantages of Swimming Pool Heat Pump?
What is the current development trend for Swimming Pool Heat Pump?
What is the working physics of the Swimming Pool Heat Pump?
1. The water temperature of the Swimming Pool Heat Pump can be set freely, and the scope of application is wider, and it can be flexibly applied to various engineering needs.
2. Swimming Pool Heat Pump uses Copeland scroll compressor, which has high efficiency, low vibration, convenient maintenance and low operational risk.
3. Swimming Pool Heat Pump has a wide operating temperature range and is more reliable in application.
4. Swimming Pool Heat Pump adopts the parallel design of compressors, which makes the operation more stable and the failure rate is lower. Even if one of them fails, the unit can still operate, reducing operational risks.
5. Swimming Pool Heat Pump meets all-around application, with cooling, heating and hot water functions.
In the competition and iteration of many heating methods, Swimming Pool Heat Pump has become the mainstream choice of swimming pool business in recent years with the characteristics of clean energy and high energy efficiency. In the past, the Swimming Pool Heat Pump was limited by technology, and as the temperature dropped, its heat pump performance also declined. Facing the requirement of constant temperature swimming pools to operate in four seasons, energy saving and high efficiency, the industry rookie frequency conversion Swimming Pool Heat Pump subversively refreshes the annual energy efficiency performance of Swimming Pool Heat Pump, stunning the market.
Swimming Pool Heat Pump is a high-quality product specially developed for indoor swimming pools. It integrates air conditioning, dehumidification, pool water heating, heat energy recovery, and fresh air treatment. It recovers and comprehensively utilizes energy in a large amount, and overcomes many problems such as high humidity and high chlorine environment. The change of different operation modes in spring, summer, autumn and winter achieves efficient and energy-saving operation.
Swimming Pool Heat Pump can fully control indoor relative humidity at 50~75%, air temperature at 27~30℃, water temperature at 26~40℃, and advanced intelligent ventilation control to maintain a high-quality indoor comfortable environment. Widely used in dry swimming pools, hot spring resorts, hotels, clubs, other fields, factories, schools and other fields that require dehumidification and constant temperature.
The working principle of Swimming Pool Heat Pump is to recycle the evaporative heat loss on the surface of the pool water, transfer it into the pool water and air, make up for the heat loss of the pool water and air, and realize the function of air conditioning and dehumidification at the same time.
Guangdong JNOD New Energy Technology Co., LTD. has various Swimming Pool Heat Pumps that can provide the best quality, and make people feel more comfortable, reliable, and consistent.