The air source heat pump type works by using a small amount of electricity to drive the compressor to run and put the whole heat pump system into operation.
Heat is continuously absorbed from the air through the evaporator.
Finally the heat absorbed and the heat generated by the electricity consumed is transferred to the water through the condenser.
This unit is determined by measuring the energy input (in this case, electricity) and the energy output (heat).
A heat pump with a CoP of 3 can produce 3 kW of heat from every 1 kW of electricity.
Modern heat pump systems can transfer three to four times more heat energy in the form of heat than they consume in electrical energy to do this job.
Other electric heating products such as the boiler, which has a COP = 1, mean that as much electricity as you want to produce heat is consumed.
So choose a product with a COP greater than 1 (JNOD's heat pump) and you'll save on your energy bills!
Furthermore, JNOD's heating and cooling heat pump has Inverter EVI technology, which will allow the heat pump to adjust its operating power according to the ambient temperature, which will be even better.
There are many different factors will influence on your heat pump's electricity consumption, for example lifestyle, size of heat pump, heating space size,etc.
Don't hesitate to contact JNOD for further advice and discussion on heat pump.
Air source heat pump water heaters have the characteristics of high efficiency and energy saving. Its energy saving effect is 4 times that of electric water heaters, 3 times that of gas water heaters, and about 2 times that of solar water heaters.
Is there a difference between an air source heat pump water heater and a normal water heater?
What are the environmental protection features of heat pump water heaters?
How does the heat pump water heater work?
Environmental protection, the heat pump water heater realizes that there is hot water whenever you want. Because it does not use electric heating elements for direct heating, compared with electric water heaters, it eliminates the potential safety hazard of electric leakage; compared with gas water heaters, there is no gas leakage, or Safety hazards such as carbon monoxide poisoning, so it has better safety performance. The air energy heat pump is regenerative, and the heating function is automatically activated according to the temperature in the water tank to ensure sufficient supply of hot water for 24 hours, so there is no such problem as the gas water heater that cannot meet the hot water for multiple faucets at the same time, nor will it There is a problem that the capacity of the electric water heater is small, and many people need to wait for a bath. The hot water is ready to use, the water output is large, and the water temperature is stable, meeting all your expectations for hot water. Because its power consumption is only one-fourth of the same amount of electric water heater, which is equivalent to using the same amount of hot water, using an air-energy heat pump, the electricity bill is only one-fourth of that of electric heating. Calculated for a family of 4, the normal consumption of hot water is about 200l/day. Electric water heaters cost about 4 yuan/day for heating, while heat pump water heaters only cost about 1 yuan/day, saving 1,000 yuan a year.
Environmental protection of heat pump water heaters: using clean energy, no waste gas, waste water, waste residue, and no thermal effect on the air. The use of environmentally friendly heat medium, cfc-free, will not cause damage to the atmospheric ozone layer. Uses of heat pump water heaters: heat pump water heaters can be used in hot water systems with a temperature requirement lower than 65°C, such as bathing, sauna, swimming pool, foot bath, beauty salon, agricultural breeding, etc. The heat pump water heater has a high energy efficiency ratio and is more energy-saving.
A heat pump water heater is essentially a heat lifting device. The function of the heat pump is to absorb heat from the surrounding environment and transfer it to the object being heated (a higher temperature object). Its working principle is the same as that of a refrigerator. It works according to the reversed Carnot cycle, the only difference is that the working temperature range is different.
Guangdong JNOD New Energy Technology Co., LTD. has been a Chinese pioneer in heat pump water heater for several years. They can provide any type of heat pump water heaters you need. At the same time, their after-sales service is also very considerate.
Heating and Cooling Heat Pump installs a four-way reversing valve on the basis of ordinary air conditioners, and changes the operation of the valve, which can exchange the functions of the evaporator and the condenser of the original air conditioner, so as to change the function of cooling indoor air. Changed to the function of heating indoor air.
What are the structural advantages of the Heating and Cooling Heat Pump?
What is the user's experience with Heating and Cooling Heat Pump?
Why the use of Heating and Cooling Heat Pump can save resources?
The evaporator of the Heating and Cooling Heat Pump adopts the method of countercurrent heat exchange for heat exchange to enhance the heat exchange effect; moreover, the heat exchange method combining fins and tube bundles is used, and each row of heat exchange tubes is arranged in a cross. The method of turbulence increases the convective heat transfer coefficient on the exhaust side and enhances the heat transfer effect;
The refrigerant tube bundle of Heating and Cooling Heat Pump is made of red copper, and the fins are made of hydrophilic aluminum foil. The condensed water in the exhausted air drips on the surface of the heat exchanger to form a water film that is conducive to heat exchange, increasing the heat exchange coefficient and enhancing the heat exchange effect;
The Heating and Cooling Heat Pump has an advanced microcomputer control system, and adopts a special programmable controller PLC for imported air-conditioning equipment, which has the ability to resist electromagnetic interference, intelligent coupling between building load and unit heating; Display, fault alarm and diagnosis functions.
The Heating and Cooling Heat Pumpis also very comfortable, clean and safe. In the past, when burning coal, it was not only dirty, tiring and troublesome, but also the temperature was not high, usually 14-16 degrees, and you had to wear cotton-padded clothes at home. Now open to 18 degrees and wear a thin sweater. If the weather is cold, turn up the temperature. Anyway, the Heating and Cooling Heat Pump is also very convenient, and you can adjust the temperature by pressing a button.
The Heating and Cooling Heat Pump unit has the dual functions of supplying cold water in summer and supplying hot water in winter. Using air as the heat source and cooling source can greatly save water and avoid the pollution of water quality. The air-cooled modular cold and hot water unit can be placed on the top floor of the building or on the outdoor platform to work, eliminating the need for a dedicated cold source machine room and boiler room.
JNOD focuses on heat pump& electric boiler R&D, manufactures and provides comprehensive energy-saving solutions. Our sales team have extensive experience of overseas markets. We provide sincere and professional services, including OEM/ODM/project services, technology support, market analysis, usage of design and composition of installation.
The Heating and Cooling Heat Pump is driven by an electric motor, uses the heat in the air as a low-temperature heat source, exchanges heat through the air conditioner condenser or evaporator, and then passes through the circulation system to extract or release heat energy, and use the unit circulation system to transfer the energy to the building. It can meet the needs of users for domestic hot water, floor heating or air conditioning.
What is the cycle between the Heating and Cooling Heat Pump and the natural environment?
What is the principle of Heating and Cooling Heat Pump?
Does the Heating and Cooling Heat Pump make noise?
The compressor outlet of the Heating and Cooling Heat Pump is high-temperature and high-pressure gas, which is transformed into a high-pressure and low-temperature vapor-liquid mixture through the heat exchange of the condenser. The low-temperature gas enters the evaporator to evaporate and absorb heat, and absorb the low-grade heat energy from the outside world (which can be rivers, lakes, groundwater, underground soil layers, air, etc., which we call water source, ground source, and air source heat pump), and finally the evaporator comes out. The low pressure gas enters the compressor to complete the cycle.
Heating and Cooling Heat Pump is an evolved product of air conditioners. An electromagnetic four-way valve (also known as a reversing valve) is installed in the refrigeration system. Through the switching direction of the four-way valve, the flow direction of the refrigerant is changed, and the air conditioner can hot. The high-temperature and high-pressure vapor-like refrigerant discharged from the compressor flows to the condenser in the heat preservation water tank, transfers heat to the tap water passing through the water tank, and then throttles and reduces the pressure through the expansion valve, and evaporates and absorbs heat in the evaporator of the main outdoor heat pump group. Use the working fluid to absorb the heat in the outdoor air. The Heating and Cooling Heat Pump absorbs the heat in the outdoor air and transfers it to the tap water in the insulated water tank. It is more energy-saving, fast and safe than simply heating with an electric heater, and the outdoor thermal energy potential is infinite.
Noise problem, almost all of today's Heating and Cooling Heat Pumps use full frequency conversion technology, indoor unit frequency conversion, heat pump host frequency conversion, fan frequency conversion, etc. The noise value of the heat pump host is below 45 decibels, and the indoor noise is still below 20 decibels. Neither users nor neighbors will be affected.
JNOD has a complete heat pump industry chain, and its products involve Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer, etc. The ultra-low temperature EVI heat pump has been widely used, too.
Guangdong JNOD New Energy Technology Co., LTD. focusing on heat pump& electric boiler R&D, manufacturing and providing comprehensive energy-saving solutions.
JNOD has a complete heat pump industry chain, and its products involves Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer,etc.The ultra-low temperature EVI heat pump has been widely used, too.
JNOD insisted on developing with technology innovation, it possessed of several national famous technicians and had invented multiply product patents. The company has been strictly implement the ISO international quality management system, and the products are of reliable guaranteed quality.
We are committed to providing customers the best hot water & heating solutions with our heat pump products, focusing on the latest technologies, strive for outstanding quality in our products and customer service.
JNOD has a complete heat pump industry chain, and its products involves Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer,etc.The ultra-low temperature EVI heat pump has been widely used, too.
Heating and cooling heat pump is a device that transfers thermal energy from a low temperature heat source to a high temperature heat source. for cooling and heating. The low-temperature heat sources usually used in heat pump installations are the media around us - air, river water, sea water, urban sewage, surface water, groundwater, reclaimed water, fire pools, or the working fluid discharged from industrial production equipment, these working fluids Often has a similar temperature to the surrounding medium.
How does the heating and cooling heat pump work?
Compared with ordinary central air conditioning refrigeration and gas wall-hung boiler heating, why does heating and cooling heat pump feel better?
What are the installation precautions for heating and cooling heat pump?
Water flows from high to low, and heat is transferred from high-temperature objects to low-temperature objects, which is a natural law. However, in real life, for the needs of agricultural irrigation, domestic water, etc., people use water pumps to send water from low places to high places. Similarly, in today's increasingly tense energy environment, in order to recover the heat in the low-temperature hot gas usually discharged into the atmosphere, the low-temperature hot water discharged into the river, etc., the heating and cooling heat pump is used to transfer the heat energy from the low-temperature objects to the high-temperature objects. Then the high temperature object is used to heat water or heating, so that the heat can be fully utilized. The working principle of the heat pump system is consistent with the working principle of the refrigeration system.
Heating and cooling heat pump has an additional heat exchange procedure in the cycle process, and the temperature difference of the system heat exchange is smaller (the air temperature of the fan coil unit in summer is 15℃-20℃, and the air temperature of the fan coil unit in winter is about 32℃) , the wind blowing out is softer, it will not take too much moisture, and the comfort is much better.
The installation location of the heating and cooling heat pump is a problem. Many people look at the installation example and think that the heat pump host with a water tank takes up too much space. The installation of the elevator apartment has to occupy a large living balcony or kitchen space. In fact, the air energy heat pump is also related to the power Related, the equipment of a large apartment is very large, and the equipment of a small apartment will be very small, and it can even be installed on an ordinary central air-conditioning unit.
Guangdong JNOD New Energy Technology Co., LTD. can provide product certification requirements for local markets; provide catalogs, technical manuals; co-exhibit with the clients in leading industry exhibitions; do promotion on the local market's media by our news release resources.
Winter has arrived, and people tend to use heat pumps as heating machines. If the heat pump unit can be installed reasonably, the service life and heating capacity of the heat pump will be improved. Let Jnod tell you how to install it, see below:
1. Unit installation location planning
1) The installation requirements of the heat pump main unit are similar to the installation requirements of the outdoor unit of the air conditioner. It can be installed on the roof, balcony, and ground. The air outlet should avoid the windward direction.
2) The distance between the main unit (wind from the side) and the surrounding walls or other obstructions should not be too small. There should be no obstructions within 1 meter of the air outlet, and ensure that the heat exhaustion and suction of the heat exchanger are not hindered.
3) There should be no obstructions within 1 meter of the air inlet of the main unit (top air outlet), and no obstructions within 2 meters of the air outlet to ensure that the heat exhaustion and suction of the heat exchanger of the main unit are not hindered.
When the unit is installed under the eaves or there are horizontal obstacles above the unit, the installation location of the unit must be in a well-ventilated place, otherwise it is easy to short-circuit the air flow, resulting in poor heat dissipation capacity of the unit.
2. Unit installation environment control
1) Try not to place it in direct sunlight.
2) Not on the window sill of the bedroom or near the bedroom.
3) There is enough distance between the air inlet and outlet to facilitate heat dissipation.
4) Places that can withstand more than 2-3 times the weight of the outdoor unit.
5) A place where there is no oily smoke or other corrosive gas.
6) A place that does not affect other factors or the environment.