











March 4th Alibaba Show For Electric Boiler And Heat Pump
Hello everyone, After a pleasant Chinese New Year holiday, we are very happy to meet you again in Alibaba's live broadcast room at 20:00 on March 4th .This time we will show you our latest electric boiler and heat pump products.
Highly welcome everyone to join and interact with us. You may get the latest market info sharing from it. Looking forward to cooperate with you.
A big discount and free sample will be offered during the show. We are waiting you.
Here's the link to watch our show:
Winter has arrived, and people tend to use heat pumps as heating machines. If the heat pump unit can be installed reasonably, the service life and heating capacity of the heat pump will be improved. Let Jnod tell you how to install it, see below:
1. Unit installation location planning
1) The installation requirements of the heat pump main unit are similar to the installation requirements of the outdoor unit of the air conditioner. It can be installed on the roof, balcony, and ground. The air outlet should avoid the windward direction.
2) The distance between the main unit (wind from the side) and the surrounding walls or other obstructions should not be too small. There should be no obstructions within 1 meter of the air outlet, and ensure that the heat exhaustion and suction of the heat exchanger are not hindered.
3) There should be no obstructions within 1 meter of the air inlet of the main unit (top air outlet), and no obstructions within 2 meters of the air outlet to ensure that the heat exhaustion and suction of the heat exchanger of the main unit are not hindered.
When the unit is installed under the eaves or there are horizontal obstacles above the unit, the installation location of the unit must be in a well-ventilated place, otherwise it is easy to short-circuit the air flow, resulting in poor heat dissipation capacity of the unit.
2. Unit installation environment control
1) Try not to place it in direct sunlight.
2) Not on the window sill of the bedroom or near the bedroom.
3) There is enough distance between the air inlet and outlet to facilitate heat dissipation.
4) Places that can withstand more than 2-3 times the weight of the outdoor unit.
5) A place where there is no oily smoke or other corrosive gas.
6) A place that does not affect other factors or the environment.
Heating and Cooling Heat Pump has the characteristics of comfort, energy saving, stability, environmental protection, safety, long service life, wide application range and one machine dual use in actual use, which makes Heating and Cooling Heat Pump more popular,favored by users.
What are the advantages of Heating and Cooling Heat Pump?
Why are more and more consumers choosing Heating and Cooling Heat Pump?
What installation conditions are the Heating and Cooling Heat Pump suitable for?
1. Safe operation and environmental protection
Heating and Cooling Heat Pump adopts the form of heat pump heating, water and electricity are completely separated, no coal or natural gas is needed, and it will not pollute the environment, and there is no need to worry about the leakage of refrigerant to pollute the environment.
2. Flexible and unlimited use
Heating and Cooling Heat Pump Compared with solar, gas, water ground source heat pumps, air source heat pumps are not limited by geology and gas supply, and are not affected by bad weather such as night, cloudy, rain and snow, so they can Realize safe operation 24 hours a day throughout the year.
3. Energy-saving technology, power saving and worry-free
Heating and Cooling Heat Pump is efficient and environmentally friendly. Compared with electric heating, it saves 75% of electricity bills per month, saving users considerable electricity bills.
Heating and Cooling Heat Pump can use floor heating as the heating end when heating. The comfort of floor heating is well known. It conforms to the traditional Chinese medicine theory of warm feet and cool top, giving people a feeling of warm feet and cool head. And the upper pass, the room is warm and cool, giving people a natural and comfortable feeling. Of course, radiators and fan coil units can also be selected at the end of indoor heating (when the water supply temperature is 35°C-45°C, the indoor floor heating can be used as the end; when the water supply temperature is 40°C-50°C, the indoor fan coil can be used as the end. The end; when the water temperature is above 55℃, the radiator can be used as the end in the room).
The main unit of the Heating and Cooling Heat Pump is similar to the outdoor unit of the central air conditioner, and can be installed in the outdoor unit of the central air conditioner, and the air energy heat pump has the functions of cooling and heating, as long as sufficient ventilation and ventilation environment is ensured, for other installations conditions are relatively low. However, when considering the installation factors of solar heating equipment, it is especially necessary to pay attention to the lighting conditions. It is difficult for ordinary elevator apartments to find suitable installation conditions.
For more information about Heating and Cooling Heat Pump, please contact Guangdong JNOD New Energy Technology Co., LTD., Ltd. has committed to providing the increasing of Heating and Cooling Heat Pump, and make them more effective, reliable, and consistent.
Heating and Cooling Heat Pump installs a four-way reversing valve on the basis of ordinary air conditioners, and changes the operation of the valve, which can exchange the functions of the evaporator and the condenser of the original air conditioner, so as to change the function of cooling indoor air. Changed to the function of heating indoor air.
What are the structural advantages of the Heating and Cooling Heat Pump?
What is the user's experience with Heating and Cooling Heat Pump?
Why the use of Heating and Cooling Heat Pump can save resources?
The evaporator of the Heating and Cooling Heat Pump adopts the method of countercurrent heat exchange for heat exchange to enhance the heat exchange effect; moreover, the heat exchange method combining fins and tube bundles is used, and each row of heat exchange tubes is arranged in a cross. The method of turbulence increases the convective heat transfer coefficient on the exhaust side and enhances the heat transfer effect;
The refrigerant tube bundle of Heating and Cooling Heat Pump is made of red copper, and the fins are made of hydrophilic aluminum foil. The condensed water in the exhausted air drips on the surface of the heat exchanger to form a water film that is conducive to heat exchange, increasing the heat exchange coefficient and enhancing the heat exchange effect;
The Heating and Cooling Heat Pump has an advanced microcomputer control system, and adopts a special programmable controller PLC for imported air-conditioning equipment, which has the ability to resist electromagnetic interference, intelligent coupling between building load and unit heating; Display, fault alarm and diagnosis functions.
The Heating and Cooling Heat Pumpis also very comfortable, clean and safe. In the past, when burning coal, it was not only dirty, tiring and troublesome, but also the temperature was not high, usually 14-16 degrees, and you had to wear cotton-padded clothes at home. Now open to 18 degrees and wear a thin sweater. If the weather is cold, turn up the temperature. Anyway, the Heating and Cooling Heat Pump is also very convenient, and you can adjust the temperature by pressing a button.
The Heating and Cooling Heat Pump unit has the dual functions of supplying cold water in summer and supplying hot water in winter. Using air as the heat source and cooling source can greatly save water and avoid the pollution of water quality. The air-cooled modular cold and hot water unit can be placed on the top floor of the building or on the outdoor platform to work, eliminating the need for a dedicated cold source machine room and boiler room.
JNOD focuses on heat pump& electric boiler R&D, manufactures and provides comprehensive energy-saving solutions. Our sales team have extensive experience of overseas markets. We provide sincere and professional services, including OEM/ODM/project services, technology support, market analysis, usage of design and composition of installation.
The heat pump water heaterabsorbs the low-temperature heat in the air, vaporizes the cold medium, and then compresses it through the compressor to increase the temperature, and then converts it through the heat exchanger to heat the water, and the compressed high-temperature heat energy is used to heat the water temperature.
What is the difference between a heat pump water heater and an air conditioner?
What are the advantages of heat pump water heater and compared with gas water heater?
What are the advantages of heat pump water heater compared to electric water heater?
When a general air conditioner is refrigerating, it absorbs the heat in the room through the phase change of the refrigerant in the evaporator (liquid to gas), and then realizes cooling through the heat release of the outdoor condenser. His heat exchange equipment is mainly finned heat exchangers. The heat pump water heater converts the low-grade energy in the air into high-grade energy that we can use. The heat is obtained by absorbing heat from the air through the phase change (endothermic) of the refrigerant in the evaporator, and then releasing heat through the indoor condenser (or jacket heat exchanger). This is his heating state. Its cooling is the same as that of general air conditioners, except that the heat exchanger may be different. General air conditioners use ordinary finned heat exchangers.
Gas water heaters heat the water temperature by burning combustible gas, and at the same time, will produce greenhouse gases such as carbon dioxide. If the continuous large amount of carbon dioxide on the earth exists in the air for a long time, it will produce a greenhouse effect on the earth's environment! The heat pump water heater only heats the water temperature with the heat in the air, and will not emit any toxic and harmful gases. In the era of energy saving and emission reduction, it is a water heater that is truly energy-saving and environmentally friendly. Secondly, gas water heaters may leak gas and cause human carbon monoxide poisoning accidents. Therefore, the safety of empty heat pump water heater is better than that of gas water heater.
We can compare heat pump water heater with electric water heater. Electric water heaters are heated with electric heating rods. The heat pump water heater heats the water temperature by absorbing heat from the air. The heat generated by the heat pump water heater consumes 1 kWh of electricity equivalent to the heat generated by the electric water heater consuming 4 kWh of electricity. In terms of energy saving, heat pump water heaters are far more energy efficient than electric water heaters. Second, in terms of security. The heat pump water heater just transfers the heat after compression heating to the water tank for heating, so the water and electricity are completely isolated. The electric water heater electric heating rod is directly heated in the water. Therefore, leakage accidents are easy to occur!
Guangdong JNOD New Energy Technology Co., LTD. is committed to providing customers the best hot water & heating solutions with our heat pump products, focusing on the latest technologies, strive for outstanding quality in our products and customer service.
Guangdong JNOD New Energy Technology Co., LTD. focusing on heat pump& electric boiler R&D, manufacturing and providing comprehensive energy-saving solutions.
JNOD has a complete heat pump industry chain, and its products involves Swimming Pool Heat Pump, House Heating & Cooling Heat Pump, Domestic Hot Water Heat Pump, Heat Pump Dehumidifier, Commercial & Industrial High Temperature Water Heating Solution, Industrial and Agricultural Heat Pump Dryer,etc.The ultra-low temperature EVI heat pump has been widely used, too.
JNOD insisted on developing with technology innovation, it possessed of several national famous technicians and had invented multiply product patents. The company has been strictly implement the ISO international quality management system, and the products are of reliable guaranteed quality.
We are committed to providing customers the best hot water & heating solutions with our heat pump products, focusing on the latest technologies, strive for outstanding quality in our products and customer service.
A heat pump is part of a heating and cooling system and is installed outside your home. Like an air conditioner, it can cool your home, but it’s also capable of providing heat.
An air-source heat pump works by transferring heat from the outside air to an indoor space. A fan draws in air from outside and transfers it to an evaporator, which is situated in the heat pump. A refrigerant circulates inside the pump, which changes its physical state and evaporates even at low temperatures. The refrigerant steam needs to be raised to a level where it can be used for your heating and hot water, so it’s compressed using a compressor. The heat produced in this process is transferred to the heating and hot water systems in your home.
In cooling mode, a heat pump absorbs heat inside your home and releases it outdoors. In heating mode, the heat pump absorbs heat from the ground or outside air (even cold air) and releases it indoors.
If you want to make your home even more eco-friendly, you could install JNOD heating & cooling heat pump, we have both R32 and R410A inverter model,.The heating capacity can be made from 10KW to 26KW, All-in-one & Monoblock type are available. This will help you to reduce your energy bills and your carbon footprint.
If you have any more questions, please contact us for get more details.
JNOD are selling R32 inverter swimming pool heat pump, its heating capacity ranges from 5.5-32Kw. So, it will be a problem for user or wholesaler to choose the suitable heating capacity for different pool sizes. Let us show you 2 methods to choose the suitable.
If you do not want to do complicated calculations and do not take into account extreme weather, you can use the following formula: 3KW for 10m³. For example, if you want to heat a 30CBM pool, (30 CBM÷10CBM)* 3KW = 9KW . So, you can choose the 9.5Kw model.
This method is used to do a very precise calculation on the heating capacity, considering the heating time, water temperature, ambient temperature, etc.
* Step 1: Calculate the needed heating capacity
In the calculation, we usually set the outlet water temperature at 28℃, primary heating time usually is 48hours.
Formula will use: Q=1.163*△t*V ;
W=Q/T
Explanation: Q = Heat Demand (KwH)
△t = Temperature Difference (℃)
V = volume of pool (m³)
W = Heat pump capacity(Kw) - usually will add 15-25% of heat loss
T = Hours for heating (H)
Example: A swimming pool 10*4*1.5m, original temperature is 18℃
Answer: set the target temperature into 28℃, heating hour into 48 hours
Q = 1.163*(28-18)*(10*4*1.5)=697.8 KwH
W= (1+15%) *Q/T=1.15*697.8/48=16.72 KW
*Step 2 : Choose the suitable heating capacity depending on working condition
The heating capacity of a heat pump is not constant; it changes with the ambient temperature. Therefore, after calculating the required heating capacity, we also need to choose the model we need according to the ambient temperature.
Still that sample, we calculate that 16.72Kw is needed. If the ambient temperature is around 24-27℃, you can choose the 17.5Kw model; if ambient temp is around 12-15℃, better to choose 25kw model.
Model | J175P32INVP | J210SP32INVP | J250SP32INVP |
Ambient Temperature:(DB/WB)27℃/24.3℃ | |||
Heating Capacity (kW) | 4.34~18.1 | 4.72~21.21 | 5.05~25.28 |
Power Input (kW) | 0.27~2.81 | 0.29~3.26 | 0.31~3.89 |
COP | 16.1~6.4 | 16.2~6.5 | 16.2~6.5 |
Ambient Temperature:(DB/WB)15℃/12℃; | |||
Heating Capacity (kW) | 3.44~13.35 | 3.51~14.21 | 3.81~17.08 |
Power Input (kW) | 0.41~2.61 | 0.43~2.78 | 0.48~3.35 |
COP | 8.3~5.1 | 8.1~5.1 | 8~5.1 |
Hope this can help you choose suitable models for swimming pool.
Any question or idea please don’t hesitate to inquire JNOD!