Heating and Cooling Heat Pump installs a four-way reversing valve on the basis of ordinary air conditioners, and changes the operation of the valve, which can exchange the functions of the evaporator and the condenser of the original air conditioner, so as to change the function of cooling indoor air. Changed to the function of heating indoor air.
What are the structural advantages of the Heating and Cooling Heat Pump?
What is the user's experience with Heating and Cooling Heat Pump?
Why the use of Heating and Cooling Heat Pump can save resources?
The evaporator of the Heating and Cooling Heat Pump adopts the method of countercurrent heat exchange for heat exchange to enhance the heat exchange effect; moreover, the heat exchange method combining fins and tube bundles is used, and each row of heat exchange tubes is arranged in a cross. The method of turbulence increases the convective heat transfer coefficient on the exhaust side and enhances the heat transfer effect;
The refrigerant tube bundle of Heating and Cooling Heat Pump is made of red copper, and the fins are made of hydrophilic aluminum foil. The condensed water in the exhausted air drips on the surface of the heat exchanger to form a water film that is conducive to heat exchange, increasing the heat exchange coefficient and enhancing the heat exchange effect;
The Heating and Cooling Heat Pump has an advanced microcomputer control system, and adopts a special programmable controller PLC for imported air-conditioning equipment, which has the ability to resist electromagnetic interference, intelligent coupling between building load and unit heating; Display, fault alarm and diagnosis functions.
The Heating and Cooling Heat Pumpis also very comfortable, clean and safe. In the past, when burning coal, it was not only dirty, tiring and troublesome, but also the temperature was not high, usually 14-16 degrees, and you had to wear cotton-padded clothes at home. Now open to 18 degrees and wear a thin sweater. If the weather is cold, turn up the temperature. Anyway, the Heating and Cooling Heat Pump is also very convenient, and you can adjust the temperature by pressing a button.
The Heating and Cooling Heat Pump unit has the dual functions of supplying cold water in summer and supplying hot water in winter. Using air as the heat source and cooling source can greatly save water and avoid the pollution of water quality. The air-cooled modular cold and hot water unit can be placed on the top floor of the building or on the outdoor platform to work, eliminating the need for a dedicated cold source machine room and boiler room.
JNOD focuses on heat pump& electric boiler R&D, manufactures and provides comprehensive energy-saving solutions. Our sales team have extensive experience of overseas markets. We provide sincere and professional services, including OEM/ODM/project services, technology support, market analysis, usage of design and composition of installation.
Water heating accounts for around 18% of the average home’s energy use. Switching to an energy-efficient heat pump water heater can make a difference on your utility bill and is an essential step in lowering the carbon footprint of your home.
We believe we JNOD are a very good heat pump supplier for you as following reason.
1. Complete Product Range:
JNOD has complete air to water heat pump product ranges, including heat pump water heaters, heating&cooling heat pump and swimming pool heat pump. We can satisfy most residential hot water and space heating need for apartment or single house.
2. Certification
Our All in one heat pump water heater gains the latest CE certificate and A+ ERP label. For some countries, distributor or install company can use them to apply the subsidies from government.
3. Multi-function
Regard to all in one hot water heat pump:
- If you look for hybrid hot water heat pump, choose the all in one heat pump. It’s a kind of electric + air source heat pump as there is an auxiliary electric heating inside as a backup.
- If there is a solar system, wires can directly connect to inverter, which can provide the electricity needed by heat pump, and then the need of grid can be reduced.
- If you want remote control, options like WiFi and RS485 can be provided.
4. OEM/ODM
If you have need of OEM/ODM, welcome to inquire us with the logo and design file you want, we will try our best to help you with better selling.
The heating and cooling heat pump is a highly efficient, energy-saving device that makes full use of inferior thermal energy. Heat can be transferred spontaneously from a hot object to a cold object, but not spontaneously in the opposite direction.
How does the heating and cooling heat pump work?
What does the operating time of the heating and cooling heat pump have to do?
What is the function of the heating and cooling heat pump?
In the heating and cooling circuit of the heat pump, the heat Q0kcal/h is obtained from the low temperature heat source (outside air or circulating water whose temperature is higher than the evaporation temperature t0) and the mechanical work ALkcal/h is consumed, while the heat of Q0kcal/h is obtained from the low temperature heat source (outside air or circulating water whose temperature is higher than the evaporation temperature t0) and the mechanical work ALkcal/h is consumed. The heating system) provides the heat of Q1kcal/h, and the relationship between these heats corresponds to the first main law of thermodynamics, ie Q1=Q0+ALkcal/h
If the heating and cooling heat pump is not used and the heat is converted by mechanical work (or the high temperature heat source is heated directly by electrical energy, the heat obtained is ALkcal/h, and after the heat pump device is used, the high temperature heat source (heating system) receives more heat is obtained: Q1-AL=Q0, kcal/h This heat is obtained from a low temperature heat source, and this heat cannot be obtained without a heat pump device. Therefore, using a heat pump device can save fuel and use waste heat.
The working cycle of a heating and cooling heat pump is exactly the opposite of that of a thermal engine. A thermal engine uses the energy of a high-temperature heat source to generate mechanical work, while a heat pump transfers heat from a low-temperature heat source to a high-temperature object by consuming mechanical work.
If the heat pump and the heat engine have two identical heat source temperatures, the thermal efficiency of the heat engine cycle is η=AL/Q1; the energy index of the thermal engine cycle – the heat conversion coefficient φ=Q1/AL, i.e. φ=1/η. The value of η is always less than 1, so the value of φ is greater than 1.
If the refrigerator and the heat pump have two identical heat source temperatures, the relationship between them is φ=Q1/AL=(Q0+AL)/AL=e+1, where η is the refrigerator's cooling coefficient. It can be seen that the minimum value of the heat transfer coefficient φ η1 and in this limit case Q0 E0, that is, no heat is absorbed from the low temperature heat source.
Green simultaneous universal heat pump for heating and cooling
We offer not only advanced, energy-efficient heat pumps with advanced inverter technology, but also a complete solution for heating, cooling and hot water supply of residential buildings.
WiFi remote control
The heating and cooling heat pump can be controlled via Wi-Fi, allowing users to operate their heat pumps anytime, anywhere.
Three in one function mode
Hot water (DHW) + Heating and cooling.
Guangdong JNOD New Energy Technology Co., LTD. Focus on research and development of heat pumps and electric boilers, manufacturing and providing comprehensive energy saving solutions.
The air source heat pump type works by using a small amount of electricity to drive the compressor to run and put the whole heat pump system into operation.
Heat is continuously absorbed from the air through the evaporator.
Finally the heat absorbed and the heat generated by the electricity consumed is transferred to the water through the condenser.
This unit is determined by measuring the energy input (in this case, electricity) and the energy output (heat).
A heat pump with a CoP of 3 can produce 3 kW of heat from every 1 kW of electricity.
Modern heat pump systems can transfer three to four times more heat energy in the form of heat than they consume in electrical energy to do this job.
Other electric heating products such as the boiler, which has a COP = 1, mean that as much electricity as you want to produce heat is consumed.
So choose a product with a COP greater than 1 (JNOD's heat pump) and you'll save on your energy bills!
Furthermore, JNOD's heating and cooling heat pump has Inverter EVI technology, which will allow the heat pump to adjust its operating power according to the ambient temperature, which will be even better.
There are many different factors will influence on your heat pump's electricity consumption, for example lifestyle, size of heat pump, heating space size,etc.
Don't hesitate to contact JNOD for further advice and discussion on heat pump.
October 1st is China's National Day. Every year of our National Day, public places wil1 hang lanterns or banners with "celebrate the National Day slogan to celebrate The square is placed on the slogan words bonsai and balloons, with a happy atmosphere to meet the National Day.
Chinese people have enjoyed a long holiday starting from every year's Oct. 1st. This one-week period is also called "golden week" . it is the biggest week for tourism in China when people have a week off to reunite with families and take trips in the past years. This makes it the second-largest holiday period in China.
JNOD staff will enjoy a 5-day break during Oct.1st to 5th. Although we are on holidays, please send us your inquiry when you are in need. JNOD professional sales team offer service anytime. If there’ s a slight delay in response during the holiday, hope for your kind understanding.
The Swimming Pool Heat Pump unit dehumidifies the indoor air while keeping the indoor air at a constant temperature. In order to save energy, the air heat is fully recycled during the operation of the equipment, and the recovered heat is used to heat the pool air or pool water through the regeneration system to ensure that the indoor air is at a constant temperature. The condensed water produced by de-temperature can be directly discharged outdoors or recycled into the swimming pool to supplement the pool water.
What are the components of Swimming Pool Heat Pump?
What are the areas of use of the Swimming Pool Heat Pump?
What are the precautions for the use of Swimming Pool Heat Pump?
1. The product composition of Swimming Pool Heat Pump:
Rack, heat exchanger, compressor, fan, pool water heat pump heating water cooling condenser, energy regulating valve, solenoid valve, power distribution cabinet, operation control system, etc.
2. Product configuration of Swimming Pool Heat Pump:
(1) Compressor: Copeland hermetic scroll compressor
(2) Heat exchanger: high-efficiency anti-corrosion copper tube sleeve coated aluminum fin or copper tube copper sheet
(3) Pool water heat pump auxiliary heating condenser: copper-titanium alloy material
(4) Energy regulating valve of refrigeration system: American Sporlan or Danfoss
(5) Fan: Sino-German joint venture fan, horizontal structure adopts Siemens or ABB motor with inner rotor pulley
(6) Main electrical appliances: Siemens components, the operation control system adopts Siemens touch screen PLC with communication interface and firefighting linkage.
Swimming Pool Heat Pump offers residential and commercial pool heaters, portable mini pool heat pumps and thermal water heating. It is an efficient, economical and green way to use environmentally friendly refrigerants R32 and R410A and titanium heat exchangers to heat the pool water. If you are looking for an energy-efficient and cost-effective way to heat your pool, we would undoubtedly recommend our Air Source Pool Heat Pump.
1. Do not use or store gasoline or other flammable and explosive gases and liquids next to the Swimming Pool Heat Pump, otherwise it will cause danger. Do not use the main power switch to turn the pool heat pump on or off, provide an operable switch.
2. Do not stuff anything into the air outlet of the Swimming Pool Heat Pump, it is very dangerous. The fan runs at high speed and may cause personal injury.
3. The ambient temperature of Swimming Pool Heat Pump is -10~38℃, and the water pressure is 0.20~0.6Mpa. If the heat pump is used in an environment other than the above conditions, it may cause the heat pump function to fail. At this time, the installation site needs to be changed.
The demand for Swimming Pool Heat Pump is also growing. Guangdong JNOD New Energy Technology Co., LTD. has been committed to providing customers with the best quality Swimming Pool Heat Pump for many years.
Heat pumps can both heat and cool because they are made with a component called a reversing valve. This valve allows the heat pump to change the flow of refrigerant in the system, so it can operate in either cooling or heating mode. During the winter, in heating mode, the heat pump absorbs heat from the surrounding air, concentrates it in the heat exchanger and blows the air into your home. In the summer months, the heat pump removes the heat and humidity from your indoor air and transfers it to the outside.
For the heating & cooling heat pump,we have both R32 and R410A inverter model,.The heating capacity can be made from 10KW to 26KW, All-in-one & Monoblock type are available.
Benefits of JNOD Heat Pumps:
Adopting Mitsubishi inverter dedicated compressor.
Which designed for the low temperature operation specially, -25℃ running stably.
Super High Efficiency A+++
Air-to-water heat pump is specially developed through cutting-edge energy-saving technology to reach the highest A+++ energy rating to meet the stringent requirements for energy efficiency.,contributing to environmental protection while significantly reducing energy bills for customers.
DC Inverter EVI Technology
DC Inverter EVI Technology can effectively reduce power consumption and improve the heating capacity of heat pump units to ensureperatures as low as -25℃,which helps to offer the users optimum house heating and hot water supply all year round.
If you want to know more information, please feel free to contact us.
Heat pump water heater is a new type of water heater. It converts air energy into heat energy through a heat pump to produce hot water. This water heater solves the disadvantage that solar energy cannot be used on rainy days. In addition, this water heater is more efficient compared to gas water heaters and electric water heaters. Environmental protection when you choose this water heater is a very good choice.
What is the main reason why air heat pump water heaters are popular in the market?
What is the workflow of a heat pump water heater?
What do you know about heat pump water heaters that can be used in hotels?
Air Source Water Heater is a new type of low carbon and environmentally friendly water heater. The operating cost of heat pump water heaters is only 1/4 of the cost of electric water heaters, which is very energy-saving and efficient. Originally, as a fourth-generation air water heater, its greatest feature is safety and money-saving! The operating costs of the air water heater are only 1/4 of the electric water heater, 1/6 of the gas water heater, 1/2 of the solar water heater, 2/3 of the fuel water heater and 3/5 of the gas heating system. The device absorbs the heat in the air to heat the cold water, and the cool air released does not pollute the environment and completely eliminates the safety risks such as flammability, explosion, electric shock and gas poisoning of ordinary water heaters.
1. The compressor compresses the low pressure refrigerant flowing back and converts it into a gas with high temperature and high pressure for discharge.
2. The high temperature and high pressure refrigerant gas flows through the copper pipe wrapped around the outside of the water tank, and the heat is passed through the copper pipe into the water tank. The cooled refrigerant becomes liquid under constant pressure and enters the evaporator after passing the expansion valve.
3. As the pressure of the evaporator is suddenly reduced, the liquid refrigerant is quickly evaporated into a gaseous state and absorbs a large amount of heat.
4. At the same time, under the action of the fan, a large amount of air flows through the outer surface of the evaporator, the energy in the air is absorbed by the evaporator, the air temperature drops quickly, and cold air is released and released.
5. The refrigerant that has absorbed a certain amount of energy is then returned to the compressor and enters the next circuit.
JNOD hot water heat pumps provide a highly efficient means of heating hot water for commercial and industrial applications. An average COP of 4.2 means that the energy efficiency is more than four times higher than that of conventional water heaters. It removes heat energy from the ambient air. This means savings of 60.75% of energy costs compared to electric water heaters.
Guangdong JNOD New Energy Technology Co., LTD. Provides marketing consulting services and business solutions to customers from over 40 countries. Customized solution for hot water supply based on the customer's market demand.